Interatrial Synchronized Pacing at the Posterosuperior Bundle: Feasibility, Mechanism, and Mid-Term Outcomes
Circulation: Arrhythmia and Electrophysiology · 2026
DOI: 10.1161/circep.125.014357 ↗Kurz gefasst
Klinische Studie in der Zeitschrift Circulation: Arrhythmia and Electrophysiology, 2026. Verfasst von Zhaohui Qiu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology (Z.Q., X.W., W.H., Z.X., Z.O., Y.Z.), Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Bundle of His, Cardiac Pacing, Artificial, Heart Atria. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Conventional atrial pacing at the right atrial appendage may impair interatrial synchrony. Posterosuperior bundle (PSB) pacing has been observed to offer anatomic accessibility by targeting the interatrial muscular connection within the superior vena cava. The study aimed to further validate the feasibility of PSB pacing and to observe mid-term outcomes through a retrospective cohort analysis. METHODS: This cohort enrolled 33 consecutive patients with pacing indications. PSB pacing was performed using a pacing lead delivered via a catheter to the medial wall of the superior vena cava, ≈1.5 cm superior to the junction of superior vena cava and right atrium. Electrophysiological and echocardiographic parameters were assessed before the procedure (baseline), acute phase, and at least 3 months after implantation. RESULTS: The mean follow-up period was 7.6±3.6 months, and PSB pacing was successful in all patients (100%), with stable lead fixation and no procedural complications, such as increased atrial capture threshold, atrial lead perforation, or atrial lead dislodgement. P-wave duration significantly shortened from baseline (120±15 ms) to follow-up (104±18 ms; P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology (Z.Q., X.W., W.H., Z.X., Z.O., Y.Z.), Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
- Department of Ultrasound (Y.T.), Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
- Cardiac Rhythm Management, Medtronic Technology Center, Medtronic, Shanghai, China (Z.R., T.S., H.L.).
ORCID-Profile: Zhaohui Qiu, Wei Hu, Yi Zhou, Tianyi Shi, Hongyang Lu
Zitieren
APA
Qiu, Z., Wu, X., Hu, W., Tang, Y., Xu, Z., Ou, Z., Zhou, Y., Ren, Z., Shi, T., & Lu, H. (2026). Interatrial Synchronized Pacing at the Posterosuperior Bundle: Feasibility, Mechanism, and Mid-Term Outcomes. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.125.014357
Vancouver
Qiu Z, Wu X, Hu W, Tang Y, Xu Z, Ou Z, et al. Interatrial Synchronized Pacing at the Posterosuperior Bundle: Feasibility, Mechanism, and Mid-Term Outcomes. Circulation: Arrhythmia and Electrophysiology. 2026. doi:10.1161/circep.125.014357
BibTeX
@article{Qiu2026,
author = {Qiu, Zhaohui and Wu, Xianhao and Hu, Wei and Tang, Yuhua and Xu, Zhongcheng and Ou, Ziming and Zhou, Yi and Ren, Zhongyuan and Shi, Tianyi and Lu, Hongyang},
title = {Interatrial Synchronized Pacing at the Posterosuperior Bundle: Feasibility, Mechanism, and Mid-Term Outcomes},
journal = {Circulation: Arrhythmia and Electrophysiology},
year = {2026},
doi = {10.1161/circep.125.014357}
}
EUVIMED