EUVIMEDEUVIMED entdecken
Crossref

Safety of magnetic resonance imaging in patients with surgically implanted permanent epicardial leads

Yue-Dong Ma, Robert E Watson, Nora E Olson, Ulrika Birgersdotter-Green, Kavisha Patel, Siva K Mulpuru, Malini Madhavan, Abhishek J Deshmukh, Ammar M Killu, Paul A Friedman, Yong-Mei Cha

Heart Rhythm · 2023

DOI: 10.1016/j.hrthm.2023.04.003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heart Rhythm, 2023. Verfasst von Yue-Dong Ma und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Pacemaker, Artificial. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Magnetic resonance imaging (MRI) safety in patients with an epicardial cardiac implantable electronic device (CIED) is uncertain. OBJECTIVE: The purpose of this study was to assess the safety and adverse effects of MRI in patients who had surgically implanted epicardial CIED. METHODS: Patients with surgically implanted CIEDs who underwent MRI with an appropriate cardiology-radiology collaborative protocol between January 2008 and January 2021 were prospectively studied in 2 clinical centers. All patients underwent close cardiac monitoring through MRI procedures. Outcomes were compared between the epicardial CIED group and the matched non-MRI-conditional transvenous CIED group. RESULTS: Twenty-nine consecutive patients with epicardial CIED (41.4% male; mean age 43 years) underwent 52 MRIs in 57 anatomic regions. Sixteen patients had a pacemaker, 9 had a cardiac defibrillator or cardiac resynchronization therapy-defibrillator, and 4 had no device generator. No significant adverse events occurred in the epicardial or transvenous CIED groups. Battery life, pacing, sensing thresholds, lead impedance, and cardiac biomarkers were not significantly changed, except 1 patient had a transient decrease in atrial lead sensing function. CONCLUSION: MRI of CIEDs with epicardially implanted leads does not represent a greater risk than transvenous CIEDs when performed with a multidisciplinary collaborative protocol centered on patient safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantablePacemaker, ArtificialHumansMaleAdultFemaleMagnetic Resonance ImagingHeartPatient Safety

Stichwörter der Autor:innen

Cardiovascular implantable electronic deviceEpicardial leadMagnetic resonance imagingSafetyTransvenous leads

Autor:innen und Institutionen

  • Department of Cardiology, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.
  • Department of Radiology, Mayo Clinic, Rochester, Minnesota.
  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota.
  • Department of Cardiovascular Medicine, University of California, San Diego Health System, San Diego, California.
  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota. Electronic address: ycha@mayo.edu.

Zitieren

APA

Ma, Y. D., Watson, R. E., Olson, N. E., Birgersdotter-Green, U., Patel, K., Mulpuru, S. K., Madhavan, M., Deshmukh, A. J., Killu, A. M., Friedman, P. A., & Cha, Y. M. (2023). Safety of magnetic resonance imaging in patients with surgically implanted permanent epicardial leads. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2023.04.003

Vancouver

Ma YD, Watson RE, Olson NE, Birgersdotter-Green U, Patel K, Mulpuru SK, et al. Safety of magnetic resonance imaging in patients with surgically implanted permanent epicardial leads. Heart Rhythm. 2023. doi:10.1016/j.hrthm.2023.04.003

BibTeX
@article{Ma2023,
  author = {Ma, Yue-Dong and Watson, Robert E and Olson, Nora E and Birgersdotter-Green, Ulrika and Patel, Kavisha and Mulpuru, Siva K and Madhavan, Malini and Deshmukh, Abhishek J and Killu, Ammar M and Friedman, Paul A and Cha, Yong-Mei},
  title = {Safety of magnetic resonance imaging in patients with surgically implanted permanent epicardial leads},
  journal = {Heart Rhythm},
  year = {2023},
  doi = {10.1016/j.hrthm.2023.04.003}
}
Kostenlos starten →