EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Quality Systems Approach for Endoscope Reprocessing

Michelle J Alfa

Gastrointestinal Endoscopy Clinics of North America · 2020-10 · 30 (4) · 693-709

DOI: 10.1016/j.giec.2020.06.005 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Gastrointestinal Endoscopy Clinics of North America, 2020-10. Verfasst von Michelle J Alfa. Beteiligte Einrichtung: Department of Medical Microbiology, University of Manitoba, Winnipeg, Manitoba, Canada. Electronic address: michellealfa001@gmail.com. Hauptthemen laut MEDLINE: Infection Control, Quality Assurance, Health Care. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: University of Manitoba.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Several factors affect the efficacy of endoscope reprocessing, including human factors, inadequate cleaning, simethicone residuals, moisture in channels during storage, and biofilm or buildup biofilm formation. These factors all contribute to contamination of patient-ready endoscopes that may contribute to transmission of microorganisms resulting in infection and/or colonization. This article reviews monitoring as part of a quality management system that includes manual cleaning, dry storage, and culture to detect endoscope contamination. The published data for rapid tests that detect organic residuals and adenosine triphosphate to monitor manual cleaning are reviewed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Infection ControlQuality Assurance, Health CareDisinfectionEndoscopesEquipment ContaminationGuidelines as TopicHumansSystems Analysis

Stichwörter der Autor:innen

BorescopesCleaning monitoringDuodenoscopesHuman factorsHumidicator testRapid cleaning testsWet storage

Autor:innen und Institutionen

  • Department of Medical Microbiology, University of Manitoba, Winnipeg, Manitoba, Canada. Electronic address: michellealfa001@gmail.com.

Förderung

  • University of Manitoba

Zitieren

APA

Alfa, M. J. (2020). Quality Systems Approach for Endoscope Reprocessing. Gastrointestinal Endoscopy Clinics of North America, 30(4), 693-709. https://doi.org/10.1016/j.giec.2020.06.005

Vancouver

Alfa MJ. Quality Systems Approach for Endoscope Reprocessing. Gastrointestinal Endoscopy Clinics of North America. 2020;30(4):693-709. doi:10.1016/j.giec.2020.06.005

BibTeX
@article{Alfa2020,
  author = {Alfa, Michelle J},
  title = {Quality Systems Approach for Endoscope Reprocessing},
  journal = {Gastrointestinal Endoscopy Clinics of North America},
  year = {2020},
  volume = {30},
  number = {4},
  pages = {693--709},
  doi = {10.1016/j.giec.2020.06.005}
}
Kostenlos starten →