EUVIMEDEUVIMED entdecken
Crossref

Optimization of wear behavior of heat-treated Ti-6Al-7Nb biomedical alloy by response surface methodology

Syed Altaf Hussain, Manoj Panchal, K Viswanath Allamraju, Upendra Rajak, Tikendra Nath Verma, Kathirvel Brindhadevi

Environmental Research · 2023-08 · 231 · 116193

DOI: 10.1016/j.envres.2023.116193 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Research, 2023-08. Verfasst von Syed Altaf Hussain und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Rajeev Gandhi Memorial College of Engineering and Technology, Nandyal, 518501, India. Hauptthemen laut MEDLINE: Titanium, Hot Temperature. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Titanium-based metals are used most often in biomedical implant studies because they have good qualities like being biocompatible, not being poisonous, Osseo-integration, high specific properties, wear resistance, etc. The main goal of this work is to improve the wear resistance of Ti-6Al-7Nb biomedical metal by using a mix of Taguchi, ANOVA, and Grey Relational Analysis. The effect of changeable control process factors like applied load, spinning speed, and time on wear reaction measures like wear rate (WR), coefficient of friction (COF), and frictional force. The optimal combinations of wear rate, COF, and frictional force minimise wear characteristics. The L9 Taguchi orthogonal array was used to plan the experiments, which were done on a pin-on-disc set-up according to ASTM G99. To find the best set of control factors, Taguchi, ANOVA, and Grey relationship analysis were used. The results show that a load of 30 N, a speed of 700 rpm, and a time of 10 min are the best control settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumHot TemperatureFrictionAlloysSurface Properties

Stichwörter der Autor:innen

ANOVAGrey relational analysisOptimizationTaguchiTitanium alloyWear resistance

Substanzen

Ti-6Al-7Nb alloyTitaniumAlloys

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Rajeev Gandhi Memorial College of Engineering and Technology, Nandyal, 518501, India.
  • Department of Mechanical Engineering, Institute of Aeronautical Engineering, Hyderabad, Telangana state, 500043, India.
  • Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal, 462003, India. Electronic address: verma.tikks@gmail.com.
  • University Centre for Research & Development, Department of Chemistry, Chandigarh University, Mohali, 140103, India; School of Engineering, Lebanese American University, Byblos, Lebanon. Electronic address: kbrindha19@g…

Zitieren

APA

Hussain, S. A., Panchal, M., Allamraju, K. V., Rajak, U., Verma, T. N., & Brindhadevi, K. (2023). Optimization of wear behavior of heat-treated Ti-6Al-7Nb biomedical alloy by response surface methodology. Environmental Research, 231, 116193. https://doi.org/10.1016/j.envres.2023.116193

Vancouver

Hussain SA, Panchal M, Allamraju KV, Rajak U, Verma TN, Brindhadevi K. Optimization of wear behavior of heat-treated Ti-6Al-7Nb biomedical alloy by response surface methodology. Environmental Research. 2023;231:116193. doi:10.1016/j.envres.2023.116193

BibTeX
@article{Hussain2023,
  author = {Hussain, Syed Altaf and Panchal, Manoj and Allamraju, K Viswanath and Rajak, Upendra and Verma, Tikendra Nath and Brindhadevi, Kathirvel},
  title = {Optimization of wear behavior of heat-treated Ti-6Al-7Nb biomedical alloy by response surface methodology},
  journal = {Environmental Research},
  year = {2023},
  volume = {231},
  pages = {116193},
  doi = {10.1016/j.envres.2023.116193}
}
Kostenlos starten →