Fachartikel in der Zeitschrift ACS Applied Bio Materials, 2024. Verfasst von Amrit Raj Paul und 6 weiteren Autor:innen. Beteiligte Einrichtung: CSIR-Central Mechanical Engineering Research Institute, Durgapur 713209, West Bengal, India. Hauptthemen laut MEDLINE: Titanium, Alloys, Cell Survival, Biocompatible Materials. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: Indian Council of Medical Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wire arc additive manufacturing (WAAM) holds promise for producing medium to large industrial components. Application of WAAM in the manufacturing of biomedical materials has not yet been evaluated. The current study addresses two key research questions: first, the suitability of the WAAMed Ti6Al4V alloy for biomedical applications, and second, the effect of Ti6Al4V's constituents (α and β phases) on the cell viability. The WAAMed Ti6Al4V alloy was fabricated (as-deposited: AD) using a metal inert gas (MIG)-based wire arc system using an in-house designed shielding chamber filled with argon. Subsequently, samples were subjected to solution treatment (950 °C for 1 h), followed by aging at 480 °C (T1), 530 °C (T2), and 580 °C (T3) for 8 h and subsequent normalization to ambient conditions. Microstructural analysis revealed ∼45.45% of α'-Ti colonies in the as-deposited samples, reducing to 23.26% postaging at 580 °C (T3). The α-lath thickness and interstitial oxygen content in the sample were observed to be proportional to the aging temperature, peaking at 580 °C (T3). Remarkably, during tribocorrosion analysis in simulated body fluid, the 580 °C-aged T3 sample displayed the lowest corrosion rate (7.9 μm/year) and the highest coefficient of friction (CoF) at 0.58, showing the effect of increasing oxygen content in the alloy matrix. Cell studies showed significant growth at 530 and 580 °C by day 7, correlated with higher oxygen content, while other samples had declining cell density. Additionally, optimal metallurgical property ranges were identified to enhance the Ti6Al4V alloy's biocompatibility, providing crucial insights for biomedical implant development.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumAlloysCell SurvivalBiocompatible MaterialsMaterials TestingHot TemperatureAnimalsParticle SizeMiceSurface Properties

Stichwörter der Autor:innen

HOS cell cultureWAAMbiocompatibilitymicrostructuretribocorrosion

Substanzen

TitaniumAlloysBiocompatible Materialstitanium alloy (TiAl6V4)

Autor:innen und Institutionen

  • CSIR-Central Mechanical Engineering Research Institute, Durgapur 713209, West Bengal, India.
  • Academy of Scientific and Innovative Research, Ghaziabad 201002, Uttar Pradesh, India.
  • RMIT Centre for Additive Manufacturing, School of Engineering, STEM College, RMIT University, Melbourne 3000, Australia.
  • Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India.
  • RMIT Microscopy and MicroAnalysis Facility, STEM College, RMIT University, Melbourne 3000, Australia.
  • Department of Biomedical Engineering, All India Institute of Medical Sciences, New Delhi 110029, India.

ORCID-Profile: Manidipto Mukherjee, Dinesh Kalyanasundaram

Förderung

  • Indian Council of Medical Research

Zitieren

APA

Paul, A. R., Singh, S., Hirwani, J., Yadav, S., Dekiwadia, C., Mukherjee, M., & Kalyanasundaram, D. (2024). Effect of Heat Treatment on the Material Property and Cell Viability of Wire Arc Additively Manufactured Ti6Al4 V. ACS Applied Bio Materials. https://doi.org/10.1021/acsabm.4c00130

Vancouver

Paul AR, Singh S, Hirwani J, Yadav S, Dekiwadia C, Mukherjee M, et al. Effect of Heat Treatment on the Material Property and Cell Viability of Wire Arc Additively Manufactured Ti6Al4 V. ACS Applied Bio Materials. 2024. doi:10.1021/acsabm.4c00130

BibTeX
@article{Paul2024,
  author = {Paul, Amrit Raj and Singh, Sonu and Hirwani, Jaswant and Yadav, Suraj and Dekiwadia, Chaitali and Mukherjee, Manidipto and Kalyanasundaram, Dinesh},
  title = {Effect of Heat Treatment on the Material Property and Cell Viability of Wire Arc Additively Manufactured Ti6Al4 V},
  journal = {ACS Applied Bio Materials},
  year = {2024},
  doi = {10.1021/acsabm.4c00130}
}
Kostenlos starten →