Ultrafast acceleration of Synthetic MRI acquisition while maintaining quantitative values: Validation study

Masahiro Nakashima, Tatsuya Kawai, Kazuhisa Matsumoto, Takatsune Kawaguchi, Ryosuke Horino, Makoto Obara, Hirohito Kan, Toshitaka Aoki, Masato Yamada, Yoshimasa Kokubo, Takumi Fujinaga, Takumi Anai und 1 weitere

European Journal of Radiology · 2026

DOI: 10.1016/j.ejrad.2026.112950 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift European Journal of Radiology, 2026. Verfasst von Masahiro Nakashima und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan. Electronic address: masahiro.nakashima.0607@gmail…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Algorithms, Image Enhancement, Image Interpretation, Computer-Assisted. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Synthetic MRI (SyMRI) is widely used in both clinical and research settings; however, its relatively long acquisition time of approximately 5-6 min has limited its applicability to acute neurological conditions in which fast imaging is critical. The aim of this study was to validate an ultrafast SyMRI acceleration algorithm and to identify quantitative parameters that maintain high agreement with conventional protocol even under such ultrafast acquisition conditions. MATERIALS AND METHODS: Ten healthy volunteers (6 females and 4 males, median age: 27) were included. The multi-dynamic multi-echo (MDME) sequence at 3.0 T MRI were performed. Three different scan durations were used, and two types of acceleration factors-SENSE and Smart Speed AI (SSAI)-were applied, resulting in a total of three imaging protocols: 5.5-min SENSE, 4-min SSAI, and 1-min SSAI protocols. ROI measurements were performed at 15 points for each image, and quantitative values including R1, R2, T1, T2, and PD were compared. The standard deviation (SD) within the measured ROIs was also compared. Bland-Altman analysis, linear mixed-effect model, and intraclass correlation coefficient (ICC) analysis were performed. RESULTS: Overall, no significant differences were observed between the acquisition methods for R2, T2, and PD. When evaluated separately across the 15 anatomical regions, no significant differences were observed between the acquisition methods for R2 and T2. The SD within the ROIs decreased with shorter acquisition times. Inter-reader agreement for the measurements was high. CONCLUSION: R2 and T2 values showed high agreement even with acceleration in the ultrafast SyMRI with a 1-min acquisition time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingAlgorithmsImage EnhancementImage Interpretation, Computer-AssistedBrainHumansFemaleReproducibility of ResultsSensitivity and SpecificityMaleAdultAcceleration

Stichwörter der Autor:innen

AIAccelerationBrainMRISynthetic MRI

Autor:innen und Institutionen

  • Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan. Electronic address: masahiro.nakashima.0607@gmail.com.
  • Department of Radiology, Nagoya City University Midori Municipal Hospital, Nagoya, Japan.
  • Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan.
  • Philips Japan, Tokyo, Japan.
  • Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Nagoya City University Hospital, Nagoya, Japan.

Zitieren

APA

Nakashima, M., Kawai, T., Matsumoto, K., Kawaguchi, T., Horino, R., Obara, M., Kan, H., Aoki, T., Yamada, M., Kokubo, Y., Fujinaga, T., Anai, T., & Hiwatashi, A. (2026). Ultrafast acceleration of Synthetic MRI acquisition while maintaining quantitative values: Validation study. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2026.112950

Vancouver

Nakashima M, Kawai T, Matsumoto K, Kawaguchi T, Horino R, Obara M, et al. Ultrafast acceleration of Synthetic MRI acquisition while maintaining quantitative values: Validation study. European Journal of Radiology. 2026. doi:10.1016/j.ejrad.2026.112950

BibTeX
@article{Nakashima2026,
  author = {Nakashima, Masahiro and Kawai, Tatsuya and Matsumoto, Kazuhisa and Kawaguchi, Takatsune and Horino, Ryosuke and Obara, Makoto and Kan, Hirohito and Aoki, Toshitaka and Yamada, Masato and Kokubo, Yoshimasa and Fujinaga, Takumi and Anai, Takumi and Hiwatashi, Akio},
  title = {Ultrafast acceleration of Synthetic MRI acquisition while maintaining quantitative values: Validation study},
  journal = {European Journal of Radiology},
  year = {2026},
  doi = {10.1016/j.ejrad.2026.112950}
}