Free‐Running Simultaneous Imaging of the Entire Lung and Heart With Isotropic Resolution
Magnetic Resonance in Medicine · 2026-07 · 96 (1) · 161-172
DOI: 10.1002/mrm.70334 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 10.03.2026. Verfasst von Zekang Ding und 4 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shangha…. Hauptthemen laut MEDLINE: Lung, Heart, Imaging, Three-Dimensional, Magnetic Resonance Imaging. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Shanghai Science and Technology Commission Explorer Program, National Natural Science Foundation of China.
Abstract (Originalsprache)
Purpose
To enable simultaneous free‐breathing imaging of the entire lung and heart with isotropic resolution at 1.5 T for the diagnosis of cardiopulmonary disorders, while reducing scan time and minimizing the requirement for patient compliance.
Methods
A three‐dimensional radial dual‐echo balanced steady‐state free precession (bSSFP) sequence was developed to acquire cardiopulmonary data in a free‐running fashion. All acquired data were binned into different respiratory and cardiac motion states according to respiratory and cardiac signals estimated from superior–inferior navigators. A novel subspace‐based motion–compensation reconstruction algorithm was used to reconstruct five‐dimensional (5D) cardiopulmonary images. Images acquired with the dual‐echo bSSFP sequence were compared with those acquired using an ultrashort echo time gradient‐echo (GRE‐UTE) sequence. The proposed 5D imaging technique was also compared with respiration‐resolved four‐dimensional (4D) imaging in 12 healthy subjects.
Results
The dual‐echo bSSFP sequence effectively captured pulmonary signals while providing superior myocardium–blood contrast compared with the GRE‐UTE sequence. Dynamic images of the entire lungs and heart were simultaneously obtained using the proposed 5D imaging technique. By minimizing the adverse effect of cardiac motion, 5D imaging yielded clearer depiction of cardiac structures and pulmonary structures adjacent to the heart than 4D imaging.
Conclusion
A new simultaneous cardiopulmonary MRI technique was proposed in this study. Five‐dimensional dynamic images of the entire lungs and heart with an isotropic resolution of 1.5 × 1.5 × 1.5 mm 3 can be obtained from a single free‐breathing scan of approximately 10 min. This technique has the potential for structural and functional assessment of the cardiopulmonary system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
- Department of Radiology, Second Affiliated Hospital of Naval Medical University, Shanghai, China.
ORCID-Profile: Sifan Wu
Förderung
- Shanghai Science and Technology Commission Explorer Program
- National Natural Science Foundation of China
Zitieren
APA
Ding, Z., Wu, S., She, H., Fan, L., & Du, Y. P. (2026). Free‐Running Simultaneous Imaging of the Entire Lung and Heart With Isotropic Resolution. Magnetic Resonance in Medicine, 96(1), 161-172. https://doi.org/10.1002/mrm.70334
Vancouver
Ding Z, Wu S, She H, Fan L, Du YP. Free‐Running Simultaneous Imaging of the Entire Lung and Heart With Isotropic Resolution. Magnetic Resonance in Medicine. 2026;96(1):161-172. doi:10.1002/mrm.70334
BibTeX
@article{Ding2026,
author = {Ding, Zekang and Wu, Sifan and She, Huajun and Fan, Li and Du, Yiping P},
title = {Free‐Running Simultaneous Imaging of the Entire Lung and Heart With Isotropic Resolution},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {1},
pages = {161--172},
doi = {10.1002/mrm.70334}
}
EUVIMED