Photon counting CT versus multi-slice CT for radiographic evaluation of postoperative cochlear implantation: Electrode characteristics and image-quality analysis

Xu Tian, Yu Huang, Jiajing Tong, Zhiqiang Gao, Yang Zhao, Guodong Feng, Yu Chen

European Journal of Radiology · 2025

DOI: 10.1016/j.ejrad.2025.112331 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Journal of Radiology, 2025. Verfasst von Xu Tian und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Peking Union Medical College Hospital, No. 1, Shuaifuyuan, Dongcheng District, Beijing 100730, China. Hauptthemen laut MEDLINE: Cochlear Implantation, Tomography, X-Ray Computed, Cochlear Implants, Multidetector Computed Tomography. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 47 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND PURPOSE: Cochlear implant surgery is a standard treatment for severe-to-profound hearing loss. Accurate postoperative assessment of cochlear electrode is crucial for patient outcomes. Photon-counting CT (PCCT) has emerged as a novel imaging modality that may surpass multi-slice CT (MSCT) in image quality and metal artifact reduction. This study aimed to compare PCCT and MSCT in the radiographic evaluation of postoperative cochlear implantation. MATERIALS AND METHODS: A retrospective control study was conducted from March 2021 to September 2024, including 35 patients who underwent cochlear implant surgery and received either PCCT or MSCT scans postoperatively. We employ the multiplanar reconstruction (MPR) method to measure the depth of the electrode and conduct both qualitative and quantitative analysis of image quality. The electrode characteristics, anatomic structures and metal artifacts were compared between the two groups by using a four grades system. Finally, we quantitatively assessed the signal-to-noise ratio (SNR) and radiation dose between the two groups. RESULTS: The PCCT group (n = 16) demonstrated superior image quality with higher mean values of rating scores for the lateral cochlear wall, medial cochlear wall and modiolus compared to the MSCT group (n = 19). The PCCT group also showed significantly better visualization of electrode position (P < 0.001), overall image quality (P = 0.01), and fewer metal artifacts (P = 0.007). The PCCT group had significantly better signal-to-noise ratio and lower radiation dose compared to the MSCT group (P < 0.001). CONCLUSIONS: PCCT suggests potential advantages in terms of image quality, reduced metal artifacts, and lower radiation doses compared to MSCT for postoperative cochlear implant assessment. These advantages suggest that PCCT could potentially serve as a new standard in imaging protocols for patients with cochlear implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cochlear ImplantationTomography, X-Ray ComputedCochlear ImplantsMultidetector Computed TomographyHumansFemaleMaleRetrospective StudiesArtifactsCochleaMiddle AgedChild, PreschoolPhotonsChildAdultRadiation DosagePostoperative PeriodSignal-To-Noise RatioAdolescentAgedRadiographic Image Interpretation, Computer-Assisted

Stichwörter der Autor:innen

Cochlear implantationMulti-slice CTMultiplanar reconstructionPhoton-counting CT

Autor:innen und Institutionen

  • Department of Otorhinolaryngology, Peking Union Medical College Hospital, No. 1, Shuaifuyuan, Dongcheng District, Beijing 100730, China.
  • Department of Radiology, Peking Union Medical College Hospital, No. 1, Shuaifuyuan, Dongcheng District, Beijing 100730, China.
  • Department of Otorhinolaryngology, Peking Union Medical College Hospital, No. 1, Shuaifuyuan, Dongcheng District, Beijing 100730, China. Electronic address: fgdent@163.com.
  • Department of Radiology, Peking Union Medical College Hospital, No. 1, Shuaifuyuan, Dongcheng District, Beijing 100730, China. Electronic address: bjchenyu@126.com.

Zitieren

APA

Tian, X., Huang, Y., Tong, J., Gao, Z., Zhao, Y., Feng, G., & Chen, Y. (2025). Photon counting CT versus multi-slice CT for radiographic evaluation of postoperative cochlear implantation: Electrode characteristics and image-quality analysis. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2025.112331

Vancouver

Tian X, Huang Y, Tong J, Gao Z, Zhao Y, Feng G, et al. Photon counting CT versus multi-slice CT for radiographic evaluation of postoperative cochlear implantation: Electrode characteristics and image-quality analysis. European Journal of Radiology. 2025. doi:10.1016/j.ejrad.2025.112331

BibTeX
@article{Tian2025,
  author = {Tian, Xu and Huang, Yu and Tong, Jiajing and Gao, Zhiqiang and Zhao, Yang and Feng, Guodong and Chen, Yu},
  title = {Photon counting CT versus multi-slice CT for radiographic evaluation of postoperative cochlear implantation: Electrode characteristics and image-quality analysis},
  journal = {European Journal of Radiology},
  year = {2025},
  doi = {10.1016/j.ejrad.2025.112331}
}
Kostenlos starten →