EUVIMEDEUVIMED entdecken
Crossref

Artifact Reduction 3.0 T MRI in Cochlear Implantation Recipient With Diametrically Bipolar Magnets

Xiaoqing Cen iD, Meng Wang, Chunxiang Zhou, Huiwen Zhuang, Jincangjian Sun, Qin Xiong, Kaitian Chen, Guanxia Xiong

The Laryngoscope · 2025

DOI: 10.1002/lary.32114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Laryngoscope, 2025. Verfasst von Xiaoqing Cen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, The First Affiliated Hospital, Sun Yat-sen University and Institute of Otorhinolaryngology, Sun Yat-sen University…. Hauptthemen laut MEDLINE: Artifacts, Magnetic Resonance Imaging, Cochlear Implants, Cochlear Implantation. Die Arbeit nennt 21 Literaturangaben. Gefördert von: the Natural Science Foundation of Guangdong Province, China, the Plan Fund of Guangzhou, the Science National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aims to explore the clinical results of the MAVRIC‐SL sequence in 3.0 Tesla (T) magnetic resonance imaging (MRI) examination of cochlear implant recipients with diametrically bipolar magnets. Study Design Retrospective study.

Methods

Six consecutive patients implanted with diametrically bipolar magnets received a 3.0 T MRI for necessary reexaminations. The artifact volumes (cm 3 ) and maximum artifact areas (cm 2 ) were measured before and after applying the MAVRIC‐SL. Adverse events, including discomfort or pain (measured using VAS), skin temperatures, and magnet displacement, were also recorded.

Results

All enrolled patients completed the MRI scans. Significant reductions in artifact volumes and maximum areas were observed with the MAVRIC‐SL sequence compared to others ( p < 0.05 to < 0.01). Targeted disease regions, as well as the inner ear anatomy, were clearly revealed with MAVRIC‐SL. One patient (aged 12) reported pain (VAS score: 8) during the scan, while others (aged 10–36) did not experience discomfort. Neither displacement nor tilt of the internal magnet was seen.

Conclusion

The MAVRIC‐SL sequence represents a feasible and safe solution for 3 T MRI in cochlear implanters with diametrically bipolar magnets, providing a new option to meet clinical needs. Level of Evidence 4.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsMagnetic Resonance ImagingCochlear ImplantsCochlear ImplantationMagnetsHumansRetrospective StudiesMaleFemaleAdultMiddle AgedChildAdolescentAgedYoung Adult

Stichwörter der Autor:innen

MAVRIC‐SL3.0 T MRIartifact reductioncochlear implantationdiametrically bipolar magnets

Autor:innen und Institutionen

  • Department of Otorhinolaryngology, The First Affiliated Hospital, Sun Yat-sen University and Institute of Otorhinolaryngology, Sun Yat-sen University, Guangzhou, People's Republic of China.
  • Department of Radiology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China.

ORCID-Profile: Xiaoqing Cen

Förderung

  • the Natural Science Foundation of Guangdong Province, China
  • the Plan Fund of Guangzhou
  • the Science National Key Research and Development Program of China

Zitieren

APA

Cen, X., Wang, M., Zhou, C., Zhuang, H., Sun, J., Xiong, Q., Chen, K., & Xiong, G. (2025). Artifact Reduction 3.0 T MRI in Cochlear Implantation Recipient With Diametrically Bipolar Magnets. The Laryngoscope. https://doi.org/10.1002/lary.32114

Vancouver

Cen X, Wang M, Zhou C, Zhuang H, Sun J, Xiong Q, et al. Artifact Reduction 3.0 T MRI in Cochlear Implantation Recipient With Diametrically Bipolar Magnets. The Laryngoscope. 2025. doi:10.1002/lary.32114

BibTeX
@article{Cen2025,
  author = {Cen, Xiaoqing and Wang, Meng and Zhou, Chunxiang and Zhuang, Huiwen and Sun, Jincangjian and Xiong, Qin and Chen, Kaitian and Xiong, Guanxia},
  title = {Artifact Reduction 3.0 T MRI in Cochlear Implantation Recipient With Diametrically Bipolar Magnets},
  journal = {The Laryngoscope},
  year = {2025},
  doi = {10.1002/lary.32114}
}
Kostenlos starten →