Quantitative assessment of video frame interpolation in coronary angiography using a novel spatio-temporal blur metric
Physica Medica · 2026
DOI: 10.1016/j.ejmp.2026.107181 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Medica, 2026. Verfasst von David Caldwell und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, Mater Misericordiae University Hospital, Dublin, Ireland. Electronic address: davidcaldwell@mater.ie. Hauptthemen laut MEDLINE: Coronary Angiography, Image Processing, Computer-Assisted, Video Recording. Die Arbeit nennt 53 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Synthetic fluoroscopy frames interpolated between real frames have been proposed as a method of reducing radiation doses in coronary angiography. Traditional full‑reference image quality assessment (FR‑IQA) metrics often favour strongly smoothed images and correlate poorly with expert cardiologist assessment of clinical image quality. METHODS: Retrospective coronary angiography data from 29 patients (58 sequences at 7.5 and 15 frames per second) were processed using linear interpolation (LI), Residue Refinement Interpolation (RRIN) and Real‑time Intermediate Flow Estimation (RIFE) algorithms. A three‑reader observer study, based on DIMOND coronary angiography quality criteria, provided clinical image‑quality scores for each sequence. A Global Noise Index (GNI), adapted from computed tomography, and BM3D, a novel extension of an established spatial blur metric into the spatio-temporal domain, were calculated for all datasets. RESULTS: Original datasets achieved the highest observer scores for resolution and branch visibility, with RRIN significantly lower and RIFE not significantly different from originals. GNI ranked algorithms RRIN < LI ≈ RIFE < Original, indicating that RRIN achieved the greatest noise suppression but was rated inferior due to over‑smoothing. BM3D ranked algorithms Original < RIFE < RRIN < LI (lower values indicating less blur), matching the clinical rankings and showing higher blur at 7.5 fps than at 15 fps. CONCLUSIONS: BM3D provides a transparent spatio‑temporal blur metric that aligns with expert assessment of coronary angiography image quality, in contrast to traditional FR‑IQA metrics. BM3D is therefore a promising tool for objective assessment and optimisation of clinical dynamic x-ray imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medical Physics, Mater Misericordiae University Hospital, Dublin, Ireland. Electronic address: davidcaldwell@mater.ie.
- Pillar Centre for Transformative Healthcare, Mater Misericordiae University Hospital, Dublin, Ireland; School of Computing, University College Dublin, Ireland; Insight Research Ireland Centre for Data Analytics, Ireland.
- Department of Cardiology, Mass General Brigham, Boston, MA, United States of America.
- Department of Medicine, Division of Cardiology Bakar Computational Health Sciences Institute, University of California, Los Angeles, CA, United States of America.
- School of Computing, University College Dublin, Ireland; Insight Research Ireland Centre for Data Analytics, Ireland.
- Department of Medical Physics, Mater Misericordiae University Hospital, Dublin, Ireland.
Zitieren
APA
Caldwell, D., Banahan, P., Gallen, R., Gambini, L., Mathur, P., Gilligan, P., Sharp, A., Casserly, I., & Blake, G. (2026). Quantitative assessment of video frame interpolation in coronary angiography using a novel spatio-temporal blur metric. Physica Medica. https://doi.org/10.1016/j.ejmp.2026.107181
Vancouver
Caldwell D, Banahan P, Gallen R, Gambini L, Mathur P, Gilligan P, et al. Quantitative assessment of video frame interpolation in coronary angiography using a novel spatio-temporal blur metric. Physica Medica. 2026. doi:10.1016/j.ejmp.2026.107181
BibTeX
@article{Caldwell2026,
author = {Caldwell, David and Banahan, Paul and Gallen, Rory and Gambini, Laura and Mathur, Prateek and Gilligan, Paddy and Sharp, Andrew and Casserly, Ivan and Blake, Gavin},
title = {Quantitative assessment of video frame interpolation in coronary angiography using a novel spatio-temporal blur metric},
journal = {Physica Medica},
year = {2026},
doi = {10.1016/j.ejmp.2026.107181}
}
EUVIMED