EUVIMEDEUVIMED entdecken
Crossref

Pediatric coronary MR angiography with a two-minute scan using de-aliasing regularization based compressed sensing

Zhihao Xue, Guanke Cai, Xuanhong Liu, Yan Zheng, Junpu Hu, Xihong Hu, Chenxi Hu

Magnetic Resonance Imaging · 2026

DOI: 10.1016/j.mri.2026.110627 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026. Verfasst von Zhihao Xue und 6 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shangha…. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Coronary Vessels, Image Processing, Computer-Assisted, Coronary Angiography. Die Arbeit nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality, Children's Hospital of Philadelphia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Long acquisition time limits the clinical utility of coronary magnetic resonance angiography (CMRA) in pediatric populations. While deep learning-based reconstruction methods such as De-Aliasing Regularization-based Compressed Sensing (DARCS) hold promise for accelerating CMRA, its clinical feasibility in pediatric populations remains unexplored. PURPOSE: This study aims to reduce scan time and evaluate the image quality and diagnostic performance of DARCS-accelerated CMRA in pediatric coronary imaging, with a focus on coronary artery aneurysms (CAAs) detection. STUDY DESIGN: A two-phase study including retrospective technique development and prospective clinical validation was performed. METHODS: CMRA was performed using a 3.0 T scanner with a three-dimensional diaphragm-navigated, T2 prepared gradient echo sequence. In the Phase I, pediatric CMRA k-space data were retrospectively undersampled to train and test DARCS reconstruction, with comparison to SENSE, patch-based reconstruction (PROST), and hybrid deep-learning iterative reconstruction (hybrid DL-IR). In Phase II, patients prospectively underwent both conventional 3× accelerated CMRA and 8× DARCS-CMRA. Images were assessed using quantitative image metrics (peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM)), coronary artery assessments (vessel lengths, sharpness, and visual scores). Diagnostic performance for CAA detection was evaluated at both patient and vessel levels. RESULTS: A total of 123 pediatric patients were included for final analysis, including 96 for the retrospective phase and 27 for the prospective phase. DARCS outperformed the second highest-performance reconstruction method in PSNR (31.74 ± 2.17 vs. 30.69 ± 2.12, P 0.05; RCA: 3.53 ± 0.81 vs. 3.42 ± 0.81, P = 0.046 < 0.05). In the prospective phase, DARCS-CMRA achieved a 100% sensitivity and specificity in detection of CAA at both patient and vessel levels, with conventional CMRA as the reference, despite a significantly shorter scan time (92.4 ± 19.1 s vs. 208.8 ± 52.0 s). CONCLUSION: DARCS offers improved reconstruction quality for accelerated CMRA compared to conventional methods, enabling preservation of CAA diagnostic accuracy despite a two-minute scan.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance AngiographyCoronary VesselsImage Processing, Computer-AssistedCoronary AngiographyHumansChildFemaleMaleRetrospective StudiesDeep LearningProspective StudiesChild, PreschoolAdolescentSignal-To-Noise RatioAlgorithmsImaging, Three-Dimensional

Stichwörter der Autor:innen

Coronary aneurysmCoronary magnetic resonance angiographyDeep learningImage reconstructionPediatrics

Autor:innen und Institutionen

  • National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Department of Radiology, Children's Hospital, Fudan University, Shanghai, China.
  • United Imaging Healthcare, Shanghai, China.
  • Department of Radiology, Children's Hospital, Fudan University, Shanghai, China. Electronic address: huxihong@fudan.edu.cn.
  • National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Electronic address: chenxi.hu…

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Commission of Shanghai Municipality
  • Children's Hospital of Philadelphia
  • National Key Research and Development Program of China
  • Fudan University

Zitieren

APA

Xue, Z., Cai, G., Liu, X., Zheng, Y., Hu, J., Hu, X., & Hu, C. (2026). Pediatric coronary MR angiography with a two-minute scan using de-aliasing regularization based compressed sensing. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2026.110627

Vancouver

Xue Z, Cai G, Liu X, Zheng Y, Hu J, Hu X, et al. Pediatric coronary MR angiography with a two-minute scan using de-aliasing regularization based compressed sensing. Magnetic Resonance Imaging. 2026. doi:10.1016/j.mri.2026.110627

BibTeX
@article{Xue2026,
  author = {Xue, Zhihao and Cai, Guanke and Liu, Xuanhong and Zheng, Yan and Hu, Junpu and Hu, Xihong and Hu, Chenxi},
  title = {Pediatric coronary MR angiography with a two-minute scan using de-aliasing regularization based compressed sensing},
  journal = {Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1016/j.mri.2026.110627}
}
Kostenlos starten →