A novel algorithm for automated analysis of coronary CTA‐derived FFR in identifying ischemia‐specific CAD: A multicenter study
Medical Physics · 2025
DOI: 10.1002/mp.17803 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Medical Physics, 2025. Verfasst von Hongqin Liang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, 7T Magnetic Resonance Imaging Translational Medical Center, Department of Radiology, Southwest Hospital, Army Medical Univer…. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Computed Tomography Angiography, Algorithms, Coronary Artery Disease. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Shanmeng, Hongqin LIang.
Abstract (Originalsprache)
Background
Coronary artery fractional flow reserve derived from coronary computed tomography angiography (CTA) is increasingly favored due to its non‐invasive nature.
Purpose
We aim to validate the ability of a novel on‐site analysis model for computed tomography derived fractional flow reserve (CT FFR) using deep learning and level set algorithms to identify lesion‐specific ischemic coronary artery disease (CAD).
Methods
A retrospective analysis was conducted on 198 vessels from 171 patients from four medical centers who underwent CTA and invasive fractional flow reserve (FFR) examinations. Using invasive FFR and invasive coronary angiography (ICA) as reference standards, a new model based on deep learning and level set algorithm, as well as an artificial intelligence (AI) platform based on deep learning, were used to compare CT FFR values and stenosis rates.
Results
Compared with the ai platform, the new model has a single‐vessel accuracy of 85.9% [95% confidence interval (95% CI) 80–90), higher than the AI platform's 66.7% (95% CI: 59.6–73.1). The sensitivity is 82.8% (95% CI: 72.8–89.7), specificity is 88.3% (95% CI: 80.5–93.4), and the area under the curve (AUC) is 0.9 (95% CI: 0.85–0.94). The stenosis rate measured by model was much higher than ICA ( r = 0.84, p < 0.0001). Using the standard FFR threshold of 0.8, the new model accurately identified 24 vessels with FFR values between 0.75 and 0.8. The AI platform exhibits significant differences in accuracy within different stenosis ranges ( p = 0.022).
Conclusion
The novel CT FFR algorithm based on a combination of deep learning and level set algorithms to optimize coronary artery 3D reconstruction may have a potential value in fully automatic on‐site analysis of specific coronary ischemia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, 7T Magnetic Resonance Imaging Translational Medical Center, Department of Radiology, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, China.
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
- Department of Ultrasound Imaging Children's Hospital of Chongqing Medical University, Chongqing, China.
- Department of Medical and Data, Escope Innovation Academy, Beijing, China.
- Department of Radiology, Linfen Central Hospital, Linfen, China.
- Department of Interventional Radiology, UIanqab Central Hospital, UIanqab, China.
Förderung
- Shanmeng
- Hongqin LIang
Zitieren
APA
Liang, H., Wen, F., Kong, L., Li, Y., Jing, F., Sun, Z., Zhang, J., Zhang, H., Meng, S., & Wang, J. (2025). A novel algorithm for automated analysis of coronary CTA‐derived FFR in identifying ischemia‐specific CAD: A multicenter study. Medical Physics. https://doi.org/10.1002/mp.17803
Vancouver
Liang H, Wen F, Kong L, Li Y, Jing F, Sun Z, et al. A novel algorithm for automated analysis of coronary CTA‐derived FFR in identifying ischemia‐specific CAD: A multicenter study. Medical Physics. 2025. doi:10.1002/mp.17803
BibTeX
@article{Liang2025,
author = {Liang, Hongqin and Wen, Feng and Kong, Li and Li, Yue and Jing, Feihua and Sun, Zhiguo and Zhang, Jucai and Zhang, Haipeng and Meng, Shan and Wang, Jian},
title = {A novel algorithm for automated analysis of coronary CTA‐derived FFR in identifying ischemia‐specific CAD: A multicenter study},
journal = {Medical Physics},
year = {2025},
doi = {10.1002/mp.17803}
}
EUVIMED