EUVIMEDEUVIMED entdecken
Evaluationsstudie

Simulating respiratory liver motion: Development and evaluation of a deformable phantom for radiotherapy testing

Xipu Jin, Liting Shi, Wenbin Wu, Rui Zhang, Yanling Wang, Xin Gao, Jiayi Zhang

Physica Medica · 2026-06 · 146 · 105803

DOI: 10.1016/j.ejmp.2026.105803 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Physica Medica, 2026-06. Verfasst von Xipu Jin und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering (Suzhou), Division of Life Science and Medicine, University of Science and Technology of China, Hefei 230026, China;…. Hauptthemen laut MEDLINE: Phantoms, Imaging, Liver, Respiration. Die Arbeit nennt 33 Literaturangaben. Gefördert von: Jiangsu Provincial Special Program of Clinical Medical Science, Suzhou Key Industrial Technology Innovation Project, Jiangsu Provincial Key Research and Development Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE Respiratory motion during liver radiotherapy introduces geometric uncertainty in tumor targeting, which can lead to underdosing of the tumor and overdosing of adjacent healthy tissues. While adaptive radiotherapy offers a potential solution, its performance requires rigorous validation using physiologically realistic phantoms. This study developed a dynamic liver phantom that simulates respiratory-induced liver motion and deformation to serve as a platform for testing adaptive radiotherapy algorithm and clinical radiotherapy systems. METHODS Using patient imaging data, digital models of the liver parenchyma, vessels, and tumors were created. Three 3D-printed materials with distinct CT values ensured clear structural contrast. The components were assembled anatomically, with ten fiducial markers for spatial reference. The model was embedded in a sponge matrix to mimic soft tissue and enclosed in a rigid resin shell. A programmable motor drove respiratory-like motion. Biomechanical fidelity was assessed by measuring the parenchyma's elastic modulus and comparing it to real liver tissue. RESULTS At 30 mm motor displacement, the phantom deformed by 5.57 mm (superior-inferior), 1.78 mm (anterior-posterior), and 0.5 mm (left-right) on average. Elastic modulus was 22.70 kPa under small strain (vs. 34.31 kPa in real liver) and 119.42 kPa under large strain (vs. 171.47 kPa). CONCLUSION This phantom effectively replicates respiratory liver motion and deformation, offering a valuable platform for validating and improving the geometric accuracy of adaptive radiotherapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingLiverRespirationHumansMovementLiver NeoplasmsTomography, X-Ray ComputedElastic Modulus

Stichwörter der Autor:innen

Adaptive radiotherapyDeformation simulationLiver phantom

Autor:innen und Institutionen

  • School of Biomedical Engineering (Suzhou), Division of Life Science and Medicine, University of Science and Technology of China, Hefei 230026, China; Suzhou Institute of Biomedical Engineering and Technology, Chinese Ac…
  • Department of Radiology, Zhejiang Cancer Hospital, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou 310022, China.
  • Department of Radiology, The People's Hospital of Suzhou New District, Suzhou 215129, China.
  • Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China; Jinan Guoke Medical Technology Development Co., Ltd., Jinan 250109, China. Electronic address: xingaosam@163.…

Förderung

  • Jiangsu Provincial Special Program of Clinical Medical Science
  • Suzhou Key Industrial Technology Innovation Project
  • Jiangsu Provincial Key Research and Development Program
  • Taishan Industry Leading Talents
  • National Natural Science Foundation of China
  • suzhoushi ronghe tongxin zhongdian shiyanshi

Zitieren

APA

Jin, X., Shi, L., Wu, W., Zhang, R., Wang, Y., Gao, X., & Zhang, J. (2026). Simulating respiratory liver motion: Development and evaluation of a deformable phantom for radiotherapy testing. Physica Medica, 146, 105803. https://doi.org/10.1016/j.ejmp.2026.105803

Vancouver

Jin X, Shi L, Wu W, Zhang R, Wang Y, Gao X, et al. Simulating respiratory liver motion: Development and evaluation of a deformable phantom for radiotherapy testing. Physica Medica. 2026;146:105803. doi:10.1016/j.ejmp.2026.105803

BibTeX
@article{Jin2026,
  author = {Jin, Xipu and Shi, Liting and Wu, Wenbin and Zhang, Rui and Wang, Yanling and Gao, Xin and Zhang, Jiayi},
  title = {Simulating respiratory liver motion: Development and evaluation of a deformable phantom for radiotherapy testing},
  journal = {Physica Medica},
  year = {2026},
  volume = {146},
  pages = {105803},
  doi = {10.1016/j.ejmp.2026.105803}
}
Kostenlos starten →