Reconstruction of multi‐phase parametric maps in 4D‐magnetic resonance fingerprinting (4D‐MRF) by optimization of local T1 and T2 sensitivities
Medical Physics · 2024
DOI: 10.1002/mp.17001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Yat Lam Wong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: General Research Fund, University Grants Committee, Health and Medical Research Fund, NSFC Young Scientist Fund.
Abstract (Originalsprache)
Background
Time‐resolved magnetic resonance fingerprinting (MRF), or 4D‐MRF, has been demonstrated its feasibility in motion management in radiotherapy (RT). However, the prohibitive long acquisition time is one of challenges of the clinical implementation of 4D‐MRF. The shortening of acquisition time causes data insufficiency in each respiratory phase, leading to poor accuracies and consistencies of the predicted tissues’ properties of each phase.
Purpose
To develop a technique for the reconstruction of multi‐phase parametric maps in four‐dimensional magnetic resonance fingerprinting (4D‐MRF) through the optimization of local T1 and T2 sensitivities.
Methods
The proposed technique employed an iterative optimization to tailor the data arrangement of each phase by manipulation of inter‐phase frames, such that the T1 and T2 sensitivities, which were quantified by the modified Minkowski distance, of the truncated signal evolution curve was maximized. The multi‐phase signal evolution curves were modified by sliding window reconstruction and inter‐phase frame sharing (SWIFS). Motion correction (MC) and dot product matching were sequentially performed on the modified signal evolution and dictionary to reconstruct the multi‐parametric maps. The proposed technique was evaluated by numerical simulations using the extended cardiac‐torso (XCAT) phantom with regular and irregular breathing patterns, and by in vivo MRF data of three health volunteers and six liver cancer patients acquired at a 3.0 T scanner.
Results
In simulation study, the proposed SWIFS approach achieved the overall mean absolute percentage error (MAPE) of 8.62% ± 1.59% and 16.2% ± 3.88% for the eight‐phases T1 and T2 maps, respectively, in the sagittal view with irregular breathing patterns. In contrast, the overall MAPE of T1 and T2 maps generated by the conventional approach with multiple MRF repetitions were 22.1% ± 11.0% and 30.8% ± 14.9%, respectively. For in‐vivo study, the predicted mean T1 and T2 of liver by the proposed SWIFS approach were 795 ms ± 38.9 ms and 58.3 ms ± 11.7 ms, respectively.
Conclusions
Both simulation and in vivo results showed that the approach empowered by T1 and T2 sensitivities optimization and sliding window under the shortened acquisition of MRF had superior performance in the estimation of multi‐phase T1 and T2 maps as compared to the conventional approach with oversampling of MRF data.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China.
- Department of Clinical Oncology, Queen Mary Hospital, Hong Kong, China.
- Department of Clinical Oncology, The University of Hong Kong, Hong Kong, China.
- Department of Clinical Oncology, Oncology Center, St. Paul's Hospital, Hong Kong, China.
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Hong Kong, China.
- Department of Diagnostic Radiology, The University of Hong Kong, Hong Kong, China.
Förderung
- General Research Fund
- University Grants Committee, Health and Medical Research Fund
- NSFC Young Scientist Fund
Zitieren
APA
Wong, Y. L., Li, T., Liu, C., Lee, H. V., Cheung, L. A., Hui, E. S. K., Cao, P., & Cai, J. (2024). Reconstruction of multi‐phase parametric maps in 4D‐magnetic resonance fingerprinting (4D‐MRF) by optimization of local T1 and T2 sensitivities. Medical Physics. https://doi.org/10.1002/mp.17001
Vancouver
Wong YL, Li T, Liu C, Lee HV, Cheung LA, Hui ESK, et al. Reconstruction of multi‐phase parametric maps in 4D‐magnetic resonance fingerprinting (4D‐MRF) by optimization of local T1 and T2 sensitivities. Medical Physics. 2024. doi:10.1002/mp.17001
BibTeX
@article{Wong2024,
author = {Wong, Yat Lam and Li, Tian and Liu, Chenyang and Lee, Ho-Fun Victor and Cheung, Lai-Yin Andy and Hui, Edward Sai Kam and Cao, Peng and Cai, Jing},
title = {Reconstruction of multi‐phase parametric maps in 4D‐magnetic resonance fingerprinting (4D‐MRF) by optimization of local T1 and T2 sensitivities},
journal = {Medical Physics},
year = {2024},
doi = {10.1002/mp.17001}
}
EUVIMED