Dosimetrical and geometrical parameters in single-fraction lattice radiotherapy for the treatment of bulky tumors: Insights from initial clinical experience
Physica Medica · 2024
DOI: 10.1016/j.ejmp.2024.103408 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Medica, 2024. Verfasst von Alejandro Prado und 10 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Radiofísica y Protección Radiológica. Hospital Universitario HM Sanchinarro. HM Hospitales. Madrid, Spain. Electronic address: aprado…. Hauptthemen laut MEDLINE: Radiometry. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: This study aims to investigate lattice radiotherapy (LRT) for bulky tumor in 10 patients, analyzing geometrical and dosimetrical parameters and correlations among variables. METHODS: Patients were prescribed a single-fraction of 18 Gy to 50 % of each spherical vertex (1.5 cm diameter). Vertices were arranged in equidistant planes forming a triangular pattern. Center-to-center distance (Dc-c) between vertices was varied from 4 to 5 cm. A new method for calculating the valley-to-peak dose ratio (VPDR) was proposed and compared to other two from existing literature. GTV volumes (VGTV), vertex number (Nvert), low-dose related parameters and vertex D99%, D50%, and D1% were recorded. Beam-on time and Monitor Units (MU) were also evaluated. Correlations were assessed using Spearman's coefficient, with significant differences analyzed using Mann-Whitney U test. RESULTS: Tumor volumes ranged from 417 to 3615 cm3. Median vertex number was 14.5 (IQR:11.3-17.8). VPDR ranged from 0.16 to 0.28. Median D99% spanned from 10.0 to 13.7 Gy, median D50% exceeded 18.0 Gy, and median D1% surpassed 23.3 Gy. Periphery dose remained under 4.0 Gy. Plans exhibited high modulation, with median beam-on time and MU of 8.8 min (IQR:8.2-10.1) and 13,069 MU (IQR:11574-13639). Significant correlations were found between Nvert and VGTV (p < 0.01), MU (p < 0.02) and beam-on time (p < 0.01) and between Dc-c and two VPDR definitions (p < 0.02) and periphery dose (p < 0.01). Significant differences were observed among the three valley dose definitions (p < 0.01) and the three peak dose definitions (p < 0.01). CONCLUSIONS: Reporting geometrical and dosimetrical parameters in LRT is crucial, alongside the need for unified definitions of valley and peak doses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Departamento de Radiofísica y Protección Radiológica. Hospital Universitario HM Sanchinarro. HM Hospitales. Madrid, Spain. Electronic address: aprado@hmhospitales.com.
- Departamento de Radiofísica y Protección Radiológica. Hospital Universitario HM Sanchinarro. HM Hospitales. Madrid, Spain.
- Departamento de Radiofísica y Protección Radiológica. Hospital Universitario de Toledo. Toledo, Spain.
- Departamento de Oncología Radioterápica. Hospital Universitario HM Sanchinarro. HM Hospitales. Madrid, Spain.
Zitieren
APA
Prado, A., Martí, J., García de Acilu, P., Zucca, D., Ángel de la Casa, M., García, J., Alonso, L., Martínez, A., Montero, Á., Rubio, C., & Fernández-Letón, P. (2024). Dosimetrical and geometrical parameters in single-fraction lattice radiotherapy for the treatment of bulky tumors: Insights from initial clinical experience. Physica Medica. https://doi.org/10.1016/j.ejmp.2024.103408
Vancouver
Prado A, Martí J, García de Acilu P, Zucca D, Ángel de la Casa M, García J, et al. Dosimetrical and geometrical parameters in single-fraction lattice radiotherapy for the treatment of bulky tumors: Insights from initial clinical experience. Physica Medica. 2024. doi:10.1016/j.ejmp.2024.103408
BibTeX
@article{Prado2024,
author = {Prado, Alejandro and Martí, Jaime and García de Acilu, Paz and Zucca, Daniel and Ángel de la Casa, Miguel and García, Juan and Alonso, Leyre and Martínez, Ana and Montero, Ángel and Rubio, Carmen and Fernández-Letón, Pedro},
title = {Dosimetrical and geometrical parameters in single-fraction lattice radiotherapy for the treatment of bulky tumors: Insights from initial clinical experience},
journal = {Physica Medica},
year = {2024},
doi = {10.1016/j.ejmp.2024.103408}
}
EUVIMED