EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Prospective evaluation of liver shearwave elastography measurements with 3 different technologies and same day liver biopsy in patients with chronic liver disease

Sebastiana M Atzori, Yasmin Pasha, James B Maurice, Simon D Taylor-Robinson, Louise Campbell, Adrian K P Lim

Digestive and Liver Disease · 2024

DOI: 10.1016/j.dld.2023.10.020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Digestive and Liver Disease, 2024. Verfasst von Sebastiana M Atzori und 5 weiteren Autor:innen. Beteiligte Einrichtung: Liver Unit QEQM Wing St. Mary Hospital, Department of Surgery and Cancer, Imperial College London, South Wharf Road, London W1 1NY, United Kingdom; D…. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver Diseases. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens, Philips Oral Healthcare, Wellcome Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Most ultrasound-based methods for assessing liver fibrosis still need further validation with liver biopsy used as gold standard to assess their accuracy. AIMS: To assess accuracy of three shear wave elastography (SWE) methods: 1) Philips Elast Point Quantification (ElastPQTM), 2) Siemens Virtual TouchTM Quantification (VTQ) acoustic radiation force impulse (ARFI), and 3) transient elastography (TE) measured by Echosens FibroscanTM. METHODS: 160 patients underwent liver stiffness measurements (LSM) with three SWE methods immediately prior to liver biopsy. RESULTS: The number of LSM required for reliable studies could be reduced to 6 for ElastPQ and to 7 for VTQ from standard recommendations of 10. Significant fibrosis and interquartile range/median (IQR/M)> 30 were independent predictors for lower reliability for detection of liver fibrosis. Ordinal logistic regression corrected for age showed that there was a significant interaction between steatosis (p = 0.008) and lobular inflammation (p = 0.04) and VTQ (ARFI) and between lobular inflammation and TE (p = 0.006). CONCLUSIONS: We showed variations in SWE measurements using different ARFI technologies. TE and ElastPQ achieved good diagnostic performance, whereas VTQ showed lower diagnostic accuracy. The number of measurements required for reliable studies can be reduced to 6 for ElastPQ and to 7 for VTQ, which have important clinical implications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesLiver DiseasesHumansReproducibility of ResultsLiverLiver CirrhosisBiopsyInflammation

Stichwörter der Autor:innen

FibroscanLiver biopsyLiver fibrosisLiver stiffness measurementsShear wave elastography

Autor:innen und Institutionen

  • Liver Unit QEQM Wing St. Mary Hospital, Department of Surgery and Cancer, Imperial College London, South Wharf Road, London W1 1NY, United Kingdom; Department of Medicine, Sassari University Hospital, Via Enrico de Nico…
  • Liver Unit QEQM Wing St. Mary Hospital, Department of Surgery and Cancer, Imperial College London, South Wharf Road, London W1 1NY, United Kingdom.
  • Liver Unit QEQM Wing St. Mary Hospital, Department of Surgery and Cancer, Imperial College London, South Wharf Road, London W1 1NY, United Kingdom; UCL Institute for Liver and Digestive Health, Royal Free Hospital Campu…
  • Liver Unit QEQM Wing St. Mary Hospital, Department of Surgery and Cancer, Imperial College London, South Wharf Road, London W1 1NY, United Kingdom; Office of the Clinical Director, Tawazun Health, 23 Harley Street, Lond…
  • Imaging Department, Charing Cross Hospital, Imperial College Healthcare NHS Trust, Fulham Palace Road, London W6 8RF, United Kingdom.

Förderung

  • Siemens
  • Philips Oral Healthcare
  • Wellcome Trust
  • National Institute for Health and Care Research

Zitieren

APA

Atzori, S. M., Pasha, Y., Maurice, J. B., Taylor-Robinson, S. D., Campbell, L., & Lim, A. K. P. (2024). Prospective evaluation of liver shearwave elastography measurements with 3 different technologies and same day liver biopsy in patients with chronic liver disease. Digestive and Liver Disease. https://doi.org/10.1016/j.dld.2023.10.020

Vancouver

Atzori SM, Pasha Y, Maurice JB, Taylor-Robinson SD, Campbell L, Lim AKP. Prospective evaluation of liver shearwave elastography measurements with 3 different technologies and same day liver biopsy in patients with chronic liver disease. Digestive and Liver Disease. 2024. doi:10.1016/j.dld.2023.10.020

BibTeX
@article{Atzori2024,
  author = {Atzori, Sebastiana M and Pasha, Yasmin and Maurice, James B and Taylor-Robinson, Simon D and Campbell, Louise and Lim, Adrian K P},
  title = {Prospective evaluation of liver shearwave elastography measurements with 3 different technologies and same day liver biopsy in patients with chronic liver disease},
  journal = {Digestive and Liver Disease},
  year = {2024},
  doi = {10.1016/j.dld.2023.10.020}
}
Kostenlos starten →