A Simple and Reliable 2D-Shear Wave Elastography and UltraSound Coefficient Attenuation Parameter Technique in Chronic Liver Diseases
Digestive Diseases and Sciences · 2024
DOI: 10.1007/s10620-024-08444-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Digestive Diseases and Sciences, 2024. Verfasst von Christiane Stern und 4 weiteren Autor:innen. Beteiligte Einrichtung: Service d'Hépatologie, Hôpital Beaujon, 100 Boulevard du Général Leclerc, 92110, Clichy, France. christiane.stern@aphp.fr. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver Cirrhosis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The performance and reliability criteria for Aixplorer MACH30 (SS) in chronic liver diseases (CLD) have not been validated. AIMS: The objectives were to define the optimal procedure, the accuracy for fibrosis and steatosis diagnosis, and the reliability criteria using SS. METHODS: Patients had 2D-shear wave elastography (SWE) and ultraSound-guided controlled attenuation parameter (SCAP) performed in triplicate at the mid-axillary line (MAL), posterior axillary line (PAL), and anterior axillary line (AAL). Performances of SWE and SCAP were defined using transient elastography (TE ≥ 9.5 kPa) and CAP (≥ 275 dB/m) using Fibroscan (FS) as reference and validated with liver biopsy (LB). RESULTS: FS and SS data from 203 CLD patients were analyzed (55 ± 14 years; 59% male; MASLD 58%). Median TE and CAP were 6.4 kPa (2.5-66.9) and 270 dB/m (141-400). The best technique for the diagnosis of advanced fibrosis and significant steatosis was the median of three SWE values and three SCAP values at MAL, PAL, and AAL with an AUROC of 0.96 [95% CI 0.93-0.98] and 0.91 [95% CI 0.86-0.95]. Only skin-to-liver distance ≥ 2.4 cm (p = 0.012, 95% CI 1.37-13.38) was independently associated with discordance. The accuracy of SWE (≥ 8.5 kPa) and SCAP (≥ 0.44) was analyzed in 58 patients with LB. The PPV and NPV were 50% and 94%, and 71% and 88% for fibrosis and steatosis, respectively. CONCLUSION: A reliable diagnosis of advanced fibrosis and significant steatosis can be obtained with the median of three measurements in different liver portions using SS. The only non-reliable criterion is skin-to-liver distance ≥ 2.4 cm.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Service d'Hépatologie, Hôpital Beaujon, 100 Boulevard du Général Leclerc, 92110, Clichy, France. christiane.stern@aphp.fr.
- Service d'Hépato-gastroentérologie, Hôpital Pitié-Salpêtrière, Paris, France. christiane.stern@aphp.fr.
- Service d'Hépato-gastroentérologie, Hôpital Pitié-Salpêtrière, Paris, France.
- Serviço de Hepatologia, Hospital Universitario Clementino Fraga Filho, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil.
Zitieren
APA
Stern, C., Ngo, A., Villela-Nogueira, C., Thabut, D., & Ratziu, V. (2024). A Simple and Reliable 2D-Shear Wave Elastography and UltraSound Coefficient Attenuation Parameter Technique in Chronic Liver Diseases. Digestive Diseases and Sciences. https://doi.org/10.1007/s10620-024-08444-3
Vancouver
Stern C, Ngo A, Villela-Nogueira C, Thabut D, Ratziu V. A Simple and Reliable 2D-Shear Wave Elastography and UltraSound Coefficient Attenuation Parameter Technique in Chronic Liver Diseases. Digestive Diseases and Sciences. 2024. doi:10.1007/s10620-024-08444-3
BibTeX
@article{Stern2024,
author = {Stern, Christiane and Ngo, An and Villela-Nogueira, Cristiane and Thabut, Dominique and Ratziu, Vlad},
title = {A Simple and Reliable 2D-Shear Wave Elastography and UltraSound Coefficient Attenuation Parameter Technique in Chronic Liver Diseases},
journal = {Digestive Diseases and Sciences},
year = {2024},
doi = {10.1007/s10620-024-08444-3}
}
EUVIMED