EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Occlusal surface accuracy of milled and DLP-printed complete denture teeth: Effects of arch segmentation and tooth-set size

Mehmet Buğra Türkcan, Erdal Eroğlu, Kadir Kıran

Digital Dentistry Journal · 2026-12 · 4 (1) · 100137

DOI: 10.1016/j.ddj.2026.100137 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Digital Dentistry Journal, 2026-12. Verfasst von Mehmet Buğra Türkcan und 2 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This in vitro study evaluated the effects of manufacturing method, one-piece or three-segment configuration, and tooth-set size on the occlusal surface morphology of complete denture teeth relative to the reference computer-aided design (CAD) model. Materials and Methods Eighty-four maxillary tooth arches were fabricated in a balanced 2 × 2 × 3 factorial design (n = 7): digital light processing (DLP) or milling; one-piece or three-segment fabrication; and small, medium, or large tooth sets. Technology-specific photopolymer resin and prepolymerized polymethyl methacrylate (PMMA) systems were used. Occlusal evaluation regions were predefined on the reference CAD geometry. One-piece arches were aligned as a whole and segments independently to their corresponding reference regions using best-fit registration. Root mean square (RMS) deviations were calculated in millimeters; segment values were combined using an equal-weight quadratic mean. Data were analyzed using three-way analysis of variance and Bonferroni-adjusted comparisons.

Results

Overall mean RMS values were 0.0713 ± 0.0208 mm for DLP and 0.1040 ± 0.0176 mm for milling, and 0.0746 ± 0.0220 mm for three-segment and 0.1007 ± 0.0214 mm for one-piece fabrication. DLP and segmentation had lower RMS within corresponding subgroups, and RMS increased with tooth size (Bonferroni-adjusted p < 0.001). The three-way interaction was significant (p = 0.001); the method × tooth size interaction was not.

Conclusions

The factorial comparison provides quantitative data for developing the tested manufacturing protocols to reproduce CAD-defined occlusal morphology. Independent segment alignment excludes assembly-related positional errors. The small RMS differences may have negligible clinical impact in vivo, requiring validation of bonded assemblies before recommending routine three-segment fabrication.

Zitieren

APA

Türkcan, M. B., Eroğlu, E., & Kıran, K. (2026). Occlusal surface accuracy of milled and DLP-printed complete denture teeth: Effects of arch segmentation and tooth-set size. Digital Dentistry Journal, 4(1), 100137. https://doi.org/10.1016/j.ddj.2026.100137

Vancouver

Türkcan MB, Eroğlu E, Kıran K. Occlusal surface accuracy of milled and DLP-printed complete denture teeth: Effects of arch segmentation and tooth-set size. Digital Dentistry Journal. 2026;4(1):100137. doi:10.1016/j.ddj.2026.100137

BibTeX
@article{Trkcan2026,
  author = {Türkcan, Mehmet Buğra and Eroğlu, Erdal and Kıran, Kadir},
  title = {Occlusal surface accuracy of milled and DLP-printed complete denture teeth: Effects of arch segmentation and tooth-set size},
  journal = {Digital Dentistry Journal},
  year = {2026},
  volume = {4},
  number = {1},
  pages = {100137},
  doi = {10.1016/j.ddj.2026.100137}
}
Kostenlos starten →