Accuracy of bone graft loss assessment around titanium and zirconium implants at varying voxel sizes – An ex vivo CBCT study

Hugo Gaêta-Araujo, Michelle Chang, Henrique Mateus Alves Felizardo, Camila Tirapelli, Christiano Oliveira-Santos

Digital Dentistry Journal · 2025

DOI: 10.1016/j.ddj.2025.100006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Digital Dentistry Journal, 2025. Verfasst von Hugo Gaêta-Araujo und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State of Sao Paulo Research Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cone beam computed tomography (CBCT) may be used for assessing peri-implant bone graft. However, imaging parameters such as voxel size can impact the final image quality and, consequently, diagnostic accuracy. This study aimed to investigate the influence of voxel size on diagnostic accuracy of bone graft loss adjacent to titanium (Ti) and zirconium (Zr) implants using two different CBCT units. Twelve Ti and twelve Zr implants were placed in twelve edentulous dry mandibles. Gaps around the implants were filled with particulate bone graft. In half of the sample, the graft was removed on the buccal side. Images were acquired using two CBCT units (OP300 and Eagle 3D) with different voxel sizes (from 0.2 ​mm to 0.08 ​mm) and evaluated by five observers. Diagnostic values were calculated for each CBCT unit and compared between implant types and voxel sizes, using the Mann-Whitney U test and the Kruskal-Wallis test with a 5 ​% significance level. The diagnostic values for Zr implants were lower compared to Ti (p ​< ​0.05), regardless of voxel size, except for specificity (p ​≥ ​0.05). Voxel size did not significantly influence the diagnostic values (p ​≥ ​0.05) in images from the Eagle 3D unit. For the OP300, AUROC values were higher for the smallest voxel compared to the largest voxel in Zr implants (p ​< ​0.05). Diagnostic accuracy of bone graft loss is rather low around Zr implants, and smaller voxel sizes are recommended, particularly for the OP300 CBCT unit. High diagnostic accuracy is expected for bone grafting assessment around Ti implants regardless of voxel size and CBCT unit.

Förderung

  • State of Sao Paulo Research Foundation

Zitieren

APA

Gaêta-Araujo, H., Chang, M., Felizardo, H. M. A., Tirapelli, C., & Oliveira-Santos, C. (2025). Accuracy of bone graft loss assessment around titanium and zirconium implants at varying voxel sizes – An ex vivo CBCT study. Digital Dentistry Journal. https://doi.org/10.1016/j.ddj.2025.100006

Vancouver

Gaêta-Araujo H, Chang M, Felizardo HMA, Tirapelli C, Oliveira-Santos C. Accuracy of bone graft loss assessment around titanium and zirconium implants at varying voxel sizes – An ex vivo CBCT study. Digital Dentistry Journal. 2025. doi:10.1016/j.ddj.2025.100006

BibTeX
@article{GataAraujo2025,
  author = {Gaêta-Araujo, Hugo and Chang, Michelle and Felizardo, Henrique Mateus Alves and Tirapelli, Camila and Oliveira-Santos, Christiano},
  title = {Accuracy of bone graft loss assessment around titanium and zirconium implants at varying voxel sizes – An ex vivo CBCT study},
  journal = {Digital Dentistry Journal},
  year = {2025},
  doi = {10.1016/j.ddj.2025.100006}
}
Kostenlos starten →