Computational prediction of proximal sealing in endovascular abdominal aortic aneurysm repair with unfavorable necks
Computer Methods and Programs in Biomedicine · 2024-02 · 244 · 107993
DOI: 10.1016/j.cmpb.2023.107993 ↗Kurz gefasst
Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2024-02. Verfasst von L Derycke und 7 weiteren Autor:innen. Beteiligte Einrichtung: Mines Saint-Etienne, Université Jean Monnet Saint-Etienne, INSERM, SAINBIOSE U1059, F-42023 Saint-Etienne, France; Department of Vascular Surgery, Hô…. Hauptthemen laut MEDLINE: Blood Vessel Prosthesis Implantation, Endovascular Procedures, Aortic Aneurysm, Abdominal. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ANR.
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVE: Endovascular aortic aneurysm repair (EVAR) has become the standard treatment for abdominal aortic aneurysms in most centers. However, proximal sealing complications leading to endoleaks and migrations sometimes occur, particularly in unfavorable aortic anatomies and are strongly dependent on biomechanical interactions between the aortic wall and the endograft. The objective of the present work is to develop and validate a computational patient-specific model that can accurately predict these complications. METHODS: Based on pre-operative CT-scans, we developed finite element models of the aorta of 10 patients who underwent endovascular aortic aneurysm repair, 7 with standard morphologies and 3 with unfavorable anatomies. We simulated the deployment of stent grafts in each aorta by solving mechanical equilibrium with a virtual shell method. Eventually we compared the actual stent ring positions from post-operative computed-tomography-scans with the predicted simulated positions. RESULTS: A successful deployment simulation could be performed for each patient. Relative radial, transverse and longitudinal deviations were 6.3 ± 4.4%, 2.5 ± 0.9 mm and 1.4 ± 1.1 mm, respectively. CONCLUSIONS: The numerical model predicted accurately stent-graft positions in the aortic neck of 10 patients, even in complex anatomies. This shows the potential of computer simulation to anticipate possible proximal endoleak complications before EVAR interventions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mines Saint-Etienne, Université Jean Monnet Saint-Etienne, INSERM, SAINBIOSE U1059, F-42023 Saint-Etienne, France; Department of Vascular Surgery, Hôpital Paris Saint-Joseph, F-75014 Paris, France.
- Mines Saint-Etienne, Université Jean Monnet Saint-Etienne, INSERM, SAINBIOSE U1059, F-42023 Saint-Etienne, France. Electronic address: avril@emse.fr.
- PrediSurge, St Etienne, France.
- Department of Cardio-Vascular and Vascular Surgery, Hôpital Européen Georges Pompidou, F-75015 Paris, France.
- Department of Vascular and Endovascular Surgery, Hospices Civils de Lyon, Louis Pradel University, Hospital, F-69500 Bron, France.
Förderung
- ANR
Zitieren
APA
Derycke, L., Avril, S., Vermunt, J., Perrin, D., El Batti, S., Alsac, J. M., Albertini, J. N., & Millon, A. (2024). Computational prediction of proximal sealing in endovascular abdominal aortic aneurysm repair with unfavorable necks. Computer Methods and Programs in Biomedicine, 244, 107993. https://doi.org/10.1016/j.cmpb.2023.107993
Vancouver
Derycke L, Avril S, Vermunt J, Perrin D, El Batti S, Alsac JM, et al. Computational prediction of proximal sealing in endovascular abdominal aortic aneurysm repair with unfavorable necks. Computer Methods and Programs in Biomedicine. 2024;244:107993. doi:10.1016/j.cmpb.2023.107993
BibTeX
@article{Derycke2024,
author = {Derycke, L and Avril, S and Vermunt, J and Perrin, D and El Batti, S and Alsac, J-M and Albertini, J-N and Millon, A},
title = {Computational prediction of proximal sealing in endovascular abdominal aortic aneurysm repair with unfavorable necks},
journal = {Computer Methods and Programs in Biomedicine},
year = {2024},
volume = {244},
pages = {107993},
doi = {10.1016/j.cmpb.2023.107993}
}
EUVIMED