EUVIMEDEUVIMED entdecken
Crossref

Treatment of Aortoiliac Aneurysms: Compatibility of the E-liac Stent Graft (Artivion®, Iliac Branch Device) with Endurant II or IIs (Medtronic®, EVAR)

Ozan Yazar, Stefanie Willems, Pieter B Salemans, Chun-Yu Wong, Bart van Grinsven, Lee H Bouwman

CardioVascular and Interventional Radiology · 2023

DOI: 10.1007/s00270-022-03352-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift CardioVascular and Interventional Radiology, 2023. Verfasst von Ozan Yazar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular and Endovascular Surgery, Zuyderland Medical Center, Henri Dunantstraat 5, 6419PC, Heerlen, The Netherlands. o.yazar@zuyderlan…. Hauptthemen laut MEDLINE: Blood Vessel Prosthesis Implantation, Aortic Aneurysm, Abdominal, Iliac Aneurysm, Endovascular Procedures. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Iliac branch devices (IBD) are widely used to treat aortoiliac aneurysms with an unfit distal landing zone for standard endovascular aneurysm repair (EVAR). The aim of this retrospective study was to examine the treatment of aortoiliac aneurysms with the combination of the Endurant II(s) stent graft system (Medtronic®) and the E-liac stent graft (Artivion®). MATERIALS AND METHODS: Data of all patients who underwent an EVAR combined with unilateral or bilateral IBD between January 2015 and January 2020 were analyzed. Primary outcomes were technical success at implantation (successful EVAR with IBD extension placement and patency of the grafts without type 1 or type 3 endoleak), and type 1b/3 endoleak, hypogastric artery patency and IBD-related reinterventions during follow-up. Secondary outcomes were all type 1 endoleak, all reinterventions, rupture, and mortality during follow-up. RESULTS: A total of 38 patients were treated with a combination of EVAR with IBD. Technical success was 94.7% (n = 36/38). The 30-day survival was 100%. Median follow-up time was 31 months (range 8-56). During follow-up, no patients developed type 1b or type 3 endoleak and all hypogastric arteries at the side of IBD remained patent. The overall reintervention rate at 12 months follow-up was 5.3% (n = 2/38) and the IBD-related reintervention rate was 2.6% (n = 1/38). CONCLUSION: The combination of the Endurant II(s) and the E-liac stent graft system is an effective and safe procedure for patients with an aortoiliac aneurysm. We confirm the high hypogastric artery patency rate using IBD. Furthermore, these devices have a high technical success rate even when it is combined with an Endurant II(s) EVAR main body.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Vessel Prosthesis ImplantationAortic Aneurysm, AbdominalIliac AneurysmEndovascular ProceduresHumansBlood Vessel ProsthesisEndoleakStentsRetrospective StudiesTreatment OutcomeProsthesis Design

Stichwörter der Autor:innen

Aortoiliac aneurysmEndoleakEndovascular treatmentHypogastric arteryIliac branch device

Autor:innen und Institutionen

  • Department of Vascular and Endovascular Surgery, Zuyderland Medical Center, Henri Dunantstraat 5, 6419PC, Heerlen, The Netherlands. o.yazar@zuyderland.nl.
  • Department of Vascular and Endovascular Surgery, Zuyderland Medical Center, Henri Dunantstraat 5, 6419PC, Heerlen, The Netherlands.
  • Faculty of Science and Engineering, Maastricht University, Maastricht, The Netherlands.

Zitieren

APA

Yazar, O., Willems, S., Salemans, P. B., Wong, C. Y., van Grinsven, B., & Bouwman, L. H. (2023). Treatment of Aortoiliac Aneurysms: Compatibility of the E-liac Stent Graft (Artivion®, Iliac Branch Device) with Endurant II or IIs (Medtronic®, EVAR). CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-022-03352-3

Vancouver

Yazar O, Willems S, Salemans PB, Wong CY, van Grinsven B, Bouwman LH. Treatment of Aortoiliac Aneurysms: Compatibility of the E-liac Stent Graft (Artivion®, Iliac Branch Device) with Endurant II or IIs (Medtronic®, EVAR). CardioVascular and Interventional Radiology. 2023. doi:10.1007/s00270-022-03352-3

BibTeX
@article{Yazar2023,
  author = {Yazar, Ozan and Willems, Stefanie and Salemans, Pieter B and Wong, Chun-Yu and van Grinsven, Bart and Bouwman, Lee H},
  title = {Treatment of Aortoiliac Aneurysms: Compatibility of the E-liac Stent Graft (Artivion®, Iliac Branch Device) with Endurant II or IIs (Medtronic®, EVAR)},
  journal = {CardioVascular and Interventional Radiology},
  year = {2023},
  doi = {10.1007/s00270-022-03352-3}
}
Kostenlos starten →