EUVIMEDEUVIMED entdecken
Crossref

Off-the-Shelf Multibranched Endograft for Type Ia Endoleak after Endovascular Aortic Repair: A Single-Center Study of the G-Branch Endograft

Yapeng Zhu, Hongpeng Zhang, Yangyang Ge, Dan Rong, Ren Wei, Wei Guo

Annals of Vascular Surgery · 2026

DOI: 10.1016/j.avsg.2026.07.010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Vascular Surgery, 2026. Verfasst von Yapeng Zhu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, The First Medical Center, Chinese PLA General Hospital, Beijing, China; Medical School of Chinese PLA, Beijing, China. Hauptthemen laut MEDLINE: Endoleak, Endovascular Aneurysm Repair, Blood Vessel Prosthesis, Stents. Die Arbeit nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: To investigate the clinical outcomes of use of a novel off-the-shelf multibranched endovascular stent graft in patients with type Ia endoleak after endovascular aortic repair (EVAR). METHODS: Patients who received the G-Branch endograft for type Ia endoleak after EVAR at our institution between November 2021 and July 2024 were retrospectively reviewed. The G-Branch endograft system, which has a hybrid configuration comprising 2 inner branches for the celiac axis and superior mesenteric artery and 2 outer branches for the renal arteries, was used in all cases. Follow-up assessments were scheduled at 1, 6, and 12 months after the index procedure and annually thereafter. RESULTS: Technical success was achieved in all cases. No deaths, cases of spinal cord ischemia, or other major adverse events occurred within 30 days postprocedure. No type Ia or type III endoleaks were detected during a median follow-up of 24 months. One patient (14.3%) underwent reintervention for type II endoleak. All target vessels remained patent without significant stenosis. No instances of dilatation of the aneurysm sac were observed. CONCLUSION: The G-Branch endograft represents a promising option for management of type Ia endoleak after EVAR, with favorable short-term to medium-term outcomes. A large multicenter study is warranted to confirm our findings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EndoleakEndovascular Aneurysm RepairBlood Vessel ProsthesisStentsAortic Aneurysm, AbdominalBlood Vessel Prosthesis ImplantationEndovascular ProceduresHumansProsthesis DesignRetrospective StudiesTreatment OutcomeTime FactorsAgedAged, 80 and overFemaleMale

Autor:innen und Institutionen

  • Department of Vascular Surgery, The First Medical Center, Chinese PLA General Hospital, Beijing, China; Medical School of Chinese PLA, Beijing, China.
  • Department of Vascular Surgery, The First Medical Center, Chinese PLA General Hospital, Beijing, China.
  • Department of Vascular Surgery, The First Medical Center, Chinese PLA General Hospital, Beijing, China. Electronic address: guoweiplagh@sina.com.

Zitieren

APA

Zhu, Y., Zhang, H., Ge, Y., Rong, D., Wei, R., & Guo, W. (2026). Off-the-Shelf Multibranched Endograft for Type Ia Endoleak after Endovascular Aortic Repair: A Single-Center Study of the G-Branch Endograft. Annals of Vascular Surgery. https://doi.org/10.1016/j.avsg.2026.07.010

Vancouver

Zhu Y, Zhang H, Ge Y, Rong D, Wei R, Guo W. Off-the-Shelf Multibranched Endograft for Type Ia Endoleak after Endovascular Aortic Repair: A Single-Center Study of the G-Branch Endograft. Annals of Vascular Surgery. 2026. doi:10.1016/j.avsg.2026.07.010

BibTeX
@article{Zhu2026,
  author = {Zhu, Yapeng and Zhang, Hongpeng and Ge, Yangyang and Rong, Dan and Wei, Ren and Guo, Wei},
  title = {Off-the-Shelf Multibranched Endograft for Type Ia Endoleak after Endovascular Aortic Repair: A Single-Center Study of the G-Branch Endograft},
  journal = {Annals of Vascular Surgery},
  year = {2026},
  doi = {10.1016/j.avsg.2026.07.010}
}
Kostenlos starten →