EUVIMEDEUVIMED entdecken
Crossref

An automatic segmentation method with self-attention mechanism on left ventricle in gated PET/CT myocardial perfusion imaging

Yangmei Zhang, Fanghu Wang, Huiqin Wu, Yuling Yang, Weiping Xu, Shuxia Wang, Wufan Chen, Lijun Lu

Computer Methods and Programs in Biomedicine · 2023-02 · 229 · 107267

DOI: 10.1016/j.cmpb.2022.107267 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2023-02. Verfasst von Yangmei Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Sou…. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Coronary Artery Disease. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Planning Project of Guangdong Province, Basic and Applied Basic Research Foundation of Guangdong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: We aimed to propose an automatic segmentation method for left ventricular (LV) from 16 electrocardiogram (ECG) -gated 13N-NH3 PET/CT myocardial perfusion imaging (MPI) to improve the performance of LV function assessment. METHODS: Ninety-six cases with confirmed or suspected obstructive coronary artery disease (CAD) were enrolled in this research. The LV myocardial contours were delineated by physicians as ground truth. We developed an automatic segmentation method, which introduces the self-attention mechanism into 3D U-Net to capture global information of images so as to achieve fine segmentation of LV. Three cross-validation tests were performed on each gate (64 vs. 32 for training vs. validation). The effectiveness was validated by quantitative metrics (modified hausdorff distance, MHD; dice ratio, DR; 3D MHD) as well as cardiac functional parameters (end-systolic volume, ESV; end-diastolic volume, EDV; ejection fraction, EF). Furthermore, the feasibility of the proposed method was also evaluated by intra- and inter-observers with DR and 3D-MHD. RESULTS: Compared with backbone network, the proposed approach improved the average DR from 0.905 ± 0.0193 to 0.9202 ± 0.0164, and decreased the average 3D MHD from 0.4611 ± 0.0349 to 0.4304 ± 0.0339. The average relative error of LV volume between proposed method and ground truth is 1.09±3.66%, and the correlation coefficient is 0.992 ± 0.007 (P < 0.001). The EDV, ESV, EF deduced from the proposed approach were highly correlated with ground truth (r ≥ 0.864, P < 0.001), and the correlation with commercial software is fair (r ≥ 0.871, P < 0.001). DR and 3D MHD of contours and myocardium from two observers are higher than 0.899 and less than 0.5194. CONCLUSION: The proposed approach is highly feasible for automatic segmentation of the LV cavity and myocardium, with potential to benefit the precision of LV function assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial Perfusion ImagingCoronary Artery DiseaseHumansPositron Emission Tomography Computed TomographyHeart VentriclesVentricular Function, LeftReproducibility of Results

Stichwörter der Autor:innen

(13)N-NH(3) PET/CTAutomatic segmentationCoronary artery diseaseLV function assessmentSelf-attention mechanism

Autor:innen und Institutionen

  • School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China.
  • WeiLun PET Center, Department of Nuclear Medicine, Guangdong Provincial People's Hospital, Guangzhou, China.
  • School of Biomedical Engineering, Southern Medical University, Guangzhou, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China; Pazhou Lab, Guangzhou, Chi…

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Planning Project of Guangdong Province
  • Basic and Applied Basic Research Foundation of Guangdong Province

Zitieren

APA

Zhang, Y., Wang, F., Wu, H., Yang, Y., Xu, W., Wang, S., Chen, W., & Lu, L. (2023). An automatic segmentation method with self-attention mechanism on left ventricle in gated PET/CT myocardial perfusion imaging. Computer Methods and Programs in Biomedicine, 229, 107267. https://doi.org/10.1016/j.cmpb.2022.107267

Vancouver

Zhang Y, Wang F, Wu H, Yang Y, Xu W, Wang S, et al. An automatic segmentation method with self-attention mechanism on left ventricle in gated PET/CT myocardial perfusion imaging. Computer Methods and Programs in Biomedicine. 2023;229:107267. doi:10.1016/j.cmpb.2022.107267

BibTeX
@article{Zhang2023,
  author = {Zhang, Yangmei and Wang, Fanghu and Wu, Huiqin and Yang, Yuling and Xu, Weiping and Wang, Shuxia and Chen, Wufan and Lu, Lijun},
  title = {An automatic segmentation method with self-attention mechanism on left ventricle in gated PET/CT myocardial perfusion imaging},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2023},
  volume = {229},
  pages = {107267},
  doi = {10.1016/j.cmpb.2022.107267}
}
Kostenlos starten →