EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Inter-Observer Reliability in Myocardial Blood Flow Measurement Using Rb-82-PET/CT

Sebastian J Stolte iD, Ole Christopher Maas, Sebastian Kopp, Hanna Geiger, Flavio Forrer

Tomography · 27.07.2026 · 12 (8) · 108

DOI: 10.3390/tomography12080108 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, online erschienen am 27.07.2026. Verfasst von Sebastian J Stolte und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen, HOCH Health Ostschweiz, 9007 St. Gallen, Switzerland. Hauptthemen laut MEDLINE: Rubidium Radioisotopes, Positron Emission Tomography Computed Tomography, Coronary Circulation, Myocardial Perfusion Imaging. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Myocardial perfusion PET/CT, e.g., using Rb-82, enables the measurement of absolute myocardial blood flow (MBF) and, hence, the blood flow reserve, which plays a crucial role in the diagnosis of coronary artery disease. However, the values might depend on the observer’s analysis and, thus, depend on the observer’s experience. We investigated the inter-observer reliability of MBF measurements in Rb-82-PET/CT.

Methods

Thirty consecutive patients who underwent Rb-82-PET/CT for suspected myocardial ischemia were analyzed. Stress conditions were simulated using 400 µg Regadenoson. MBF was measured using Corridor 4DM software. Myocardial flow reserve (MFR) is the ratio of absolute flow measurements under stress and rest conditions. Four different physicians with different levels of experience (two senior physicians and two residents) measured the MBF. The experience of the two residents was one year of experience and no previous experience, respectively. Intraclass correlation coefficients (ICC) were calculated for MBF and MFR in the three main vascular territories as well as in the whole left ventricle. Additionally, the left ventricular ejection fraction (EF) was determined.

Results

The evaluation of MBF showed an excellent correlation between all observers, indicated by a low inter-observer variability. Comparing the two different levels of experience, senior physicians showed a slightly higher accordance in MBF assessment (ICC ranging from 0.9 to 0.98) than the residents (ICC ranging from 0.86 to 0.94). The MFR calculations showed a slightly lower reliability due to the accumulation of variability in rest and stress measurements (ICC between 0.78 and 0.81), still indicating a good reliability. The EF calculations also showed a good reliability among the different observers (ICC 0.83).

Conclusions

Measurement of MBF, MFR and EF in Rb-82-PET/CT is highly robust with a very low inter-observer variability. A slightly higher inter-observer reliability was found for more experienced physicians.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Rubidium RadioisotopesPositron Emission Tomography Computed TomographyCoronary CirculationMyocardial Perfusion ImagingMyocardial IschemiaCoronary Artery DiseaseHumansReproducibility of ResultsObserver VariationFemaleMaleAgedMiddle AgedRadiopharmaceuticalsFractional Flow Reserve, MyocardialPurinesPyrazoles

Stichwörter der Autor:innen

Rb-82-PET/CTcardiac perfusion imagingflow reserveinter-observer reliabilitymyocardial blood flow

Substanzen

Rubidium RadioisotopesRubidium-82RadiopharmaceuticalsregadenosonPurinesPyrazoles

Autor:innen und Institutionen

  • Department of Radiology and Nuclear Medicine, Cantonal Hospital St. Gallen, HOCH Health Ostschweiz, 9007 St. Gallen, Switzerland.
  • Faculty of Medicine, University of Basel, 4001 Basel, Switzerland.
  • Department of Cardiology, Cantonal Hospital St. Gallen, HOCH Health Ostschweiz, 9007 St. Gallen, Switzerland.

ORCID-Profile: Sebastian J Stolte

Zitieren

APA

Stolte, S. J., Maas, O. C., Kopp, S., Geiger, H., & Forrer, F. (2026). Inter-Observer Reliability in Myocardial Blood Flow Measurement Using Rb-82-PET/CT. Tomography, 12(8), 108. https://doi.org/10.3390/tomography12080108

Vancouver

Stolte SJ, Maas OC, Kopp S, Geiger H, Forrer F. Inter-Observer Reliability in Myocardial Blood Flow Measurement Using Rb-82-PET/CT. Tomography. 2026;12(8):108. doi:10.3390/tomography12080108

BibTeX
@article{Stolte2026,
  author = {Stolte, Sebastian J and Maas, Ole Christopher and Kopp, Sebastian and Geiger, Hanna and Forrer, Flavio},
  title = {Inter-Observer Reliability in Myocardial Blood Flow Measurement Using Rb-82-PET/CT},
  journal = {Tomography},
  year = {2026},
  volume = {12},
  number = {8},
  pages = {108},
  doi = {10.3390/tomography12080108}
}
Kostenlos starten →