The Turkish version of the 5-item Dry Eye Questionnaire (T-DEQ-5): Translation, validity, and reliability
Contact Lens and Anterior Eye · 2024
DOI: 10.1016/j.clae.2024.102309 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Contact Lens and Anterior Eye, 2024. Verfasst von Semra Akkaya Turhan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Marmara University Medical School, Istanbul, Maltepe, Turkey. Electronic address: semra.akkaya@marmara.edu.tr. Hauptthemen laut MEDLINE: Dry Eye Syndromes, Surveys and Questionnaires, Translations. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate the reliability and validity of Turkish translation of the 5-item Dry Eye Questionnaire (T-DEQ-5) and to compare it with the Ocular Surface Disease Index (OSDI) questionnaire, tear break-up time (TBUT), corneal staining, and Schirmer test results. METHODS: The linguistic validation procedures adopted internationally, including forward translations, backward translation into English, examination of the translation quality, and a pilot test on 10 subjects, were employed. The translated and validated questionnaire was applied to 25 subjects two-time points (second time within three days) to evaluate the intra-test reliability. One hundred subjects were recruited for the study. They underwent an ophthalmic examination, including Schirmer tests, TBUT, and ocular surface staining (OSS) after completing OSDI questionnaire. Receiver operating characteristics (ROC) were assessed to determine sensitivity and specificity of the T-DEQ-5. RESULTS: The mean age of subjects was 45.7 ± 16.2 years, with 65 % being female. Overall, the test-retest reliability was excellent with an intra-class correlation coefficient value of 0.95 (95 % CI 0.90-0.98, p < 0.001). The Cronbach's alpha reliability coefficient was 0.90, which demonstrated a strong level of internal consistency of the T-DEQ-5. Using ROC analysis to compare the results of the T-DEQ-5 with those of the OSDI, the area under the curve was found 0.95, with an optimal cut-off threshold of 6, resulting in 81 % sensitivity and 91 % specificity. Establishing the diagnosis based on a positive OSDI (≥13) and at least one positive sign (TBUT and/or OSS) yielded a sensitivity of 95 % and a specificity of 87 % at the cut-off threshold of 6. CONCLUSION: The Turkish version of the DEQ-5 is a valid and reliable questionnaire and capable of differentiating patients with dry eye.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Marmara University Medical School, Istanbul, Maltepe, Turkey. Electronic address: semra.akkaya@marmara.edu.tr.
- Department of Ophthalmology, Kocaeli Kandıra M. Kazım Dinç State Hospital, Kocaeli, Kandıra, Turkey.
- Department of Ophthalmology, Sinop Boyabat 75, Yıl State Hospital, Sinop, Boyabat, Turkey.
- Beetham Eye Institute, Joslin Diabetes Center, Boston, MA, USA; Department of Ophthalmology, Harvard Medical School, Boston, MA, USA.
- Department of Physical Therapy and Rehabilitation, Marmara University Medical School, Istanbul, Maltepe, Turkey.
- Department of Ophthalmology and Visual Sciences, West Virginia University Eye Institute, Morgantown, WV, USA.
Zitieren
APA
Turhan, S. A., Vurgun, E. B., Yalçındağ, E., Gülkaş, S., Toprak, C. Ş., & Toker, A. E. (2024). The Turkish version of the 5-item Dry Eye Questionnaire (T-DEQ-5): Translation, validity, and reliability. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2024.102309
Vancouver
Turhan SA, Vurgun EB, Yalçındağ E, Gülkaş S, Toprak CŞ, Toker AE. The Turkish version of the 5-item Dry Eye Questionnaire (T-DEQ-5): Translation, validity, and reliability. Contact Lens and Anterior Eye. 2024. doi:10.1016/j.clae.2024.102309
BibTeX
@article{Turhan2024,
author = {Turhan, Semra Akkaya and Vurgun, Elif Bagatur and Yalçındağ, Ece and Gülkaş, Samet and Toprak, Canan Şanal and Toker, Ayşe Ebru},
title = {The Turkish version of the 5-item Dry Eye Questionnaire (T-DEQ-5): Translation, validity, and reliability},
journal = {Contact Lens and Anterior Eye},
year = {2024},
doi = {10.1016/j.clae.2024.102309}
}
EUVIMED