EUVIMEDEUVIMED entdecken
Crossref

Intrasession repeatability and interobserver reproducibility of ICP Tearscope measurements of tear meniscus height and non-invasive breakup time

Ana Rosa Barrio, Mariano González-Pérez, Pedro Arriola-Villalobos, Beatriz Antona

Contact Lens and Anterior Eye · 2025

DOI: 10.1016/j.clae.2024.102333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2025. Verfasst von Ana Rosa Barrio und 3 weiteren Autor:innen. Beteiligte Einrichtung: Applied Vision Research Group, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain. Electronic address: arbarrio@u…. Hauptthemen laut MEDLINE: Tears, Dry Eye Syndromes, Diagnostic Techniques, Ophthalmological. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: European Regional Development Fund, Carlos III Health Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To examine intrasession repeatability and interobserver reproducibility of tear meniscus height (TMH) and non-invasive tear breakup time (NIBUT) measurements provided by ICP Tearscope, and their agreement with Keratograph 5 M measurements in persons with and without dry eye. METHODS: Participants were 48 individuals with dry eye disease (DED) and 44 healthy controls. To determine intrasession repeatability, two consecutive TMH and NIBUT measurements were carried out by a single experienced examiner using ICP Tearscope. For interobserver reproducibility, a second masked investigator measured TMH and NIBUT on the first image and video captured by the examiner. Keratograph 5 M measurements of both variables were carried out by the same examiner. Repeatability and reproducibility were evaluated through within-subject standard deviation (Sw), coefficient of variation (CoV), intraclass correlation coefficient (ICC) and Bland-Altman plots (bias and limits of agreement (LoA)). RESULTS: The TMH measurement with ICP Tearscope showed both, a moderate intrasession repeatability (Sw = 0.045, CoV 0.684) and interobserver reproducibility (Sw = 0.032, CoV 0.926). The NIBUT measurement showed worse intrasession repeatability in the DED group (CoV = 27.53 %) than in the Control group (CoV = 13.31 %). Even though similar Sw, LoA and ICC values were observed in both groups (Sw = 2.55 s and 2.34 s; LoA = -6.60 to 5.18 s and -4.82 to 6.51 s, Control and DED respectively, ICCs > 0.95). Interobserver reproducibility indicated a moderate amount of variability with CoV ≤ 15.01 % recorded in both groups. Agreement between the two devices was poor. Limits of agreement were not clinically acceptable for TMH (LoA = -0.19 to 0.14 mm and -0.16 to 0.13 mm, Control and DED, respectively) and for NIBUT (LoA = -12.74 to 14.08 s and -12.19 to 12.87 s, Control and DED, respectively). CONCLUSIONS: ICP Tearscope provides TMH and NIBUT measurements that show weak repeatability and moderate interobserver reproducibility. This device is not interchangeable with the Keratograph 5 M.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TearsDry Eye SyndromesDiagnostic Techniques, OphthalmologicalHumansReproducibility of ResultsMaleFemaleObserver VariationAdultMiddle AgedYoung Adult

Stichwörter der Autor:innen

AgreementNon-invasive tear breakup timeRepeatabilityReproducibilityTear meniscus heightTearscope

Autor:innen und Institutionen

  • Applied Vision Research Group, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain. Electronic address: arbarrio@ucm.es.
  • Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain.
  • Servicio de Oftalmología, Hospital Clínico San Carlos; Departamento de Inmunología, Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid (UCM); IdISSC, Madrid, Spain.
  • Applied Vision Research Group, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain.

Förderung

  • European Regional Development Fund
  • Carlos III Health Institute

Zitieren

APA

Barrio, A. R., González-Pérez, M., Arriola-Villalobos, P., & Antona, B. (2025). Intrasession repeatability and interobserver reproducibility of ICP Tearscope measurements of tear meniscus height and non-invasive breakup time. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2024.102333

Vancouver

Barrio AR, González-Pérez M, Arriola-Villalobos P, Antona B. Intrasession repeatability and interobserver reproducibility of ICP Tearscope measurements of tear meniscus height and non-invasive breakup time. Contact Lens and Anterior Eye. 2025. doi:10.1016/j.clae.2024.102333

BibTeX
@article{Barrio2025,
  author = {Barrio, Ana Rosa and González-Pérez, Mariano and Arriola-Villalobos, Pedro and Antona, Beatriz},
  title = {Intrasession repeatability and interobserver reproducibility of ICP Tearscope measurements of tear meniscus height and non-invasive breakup time},
  journal = {Contact Lens and Anterior Eye},
  year = {2025},
  doi = {10.1016/j.clae.2024.102333}
}
Kostenlos starten →