Pre-processing stability of routine clinical chemistry analytes in a clotting tube; investigating the (un)suitability for at-home sample collection
Clinica Chimica Acta · 2025
DOI: 10.1016/j.cca.2024.120035 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinica Chimica Acta, 2025. Verfasst von Maaike Roelofs und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, The Netherlands Cancer Institute, Amsterdam, the Netherlands. Hauptthemen laut MEDLINE: Blood Specimen Collection, Blood Chemical Analysis, Blood Coagulation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: There is a growing interest in self-collection of blood for clinical applications. Next to allowing patients to self-sample blood, adequate sample stability of the analyte is essential to provide an accurate and reliable test result. This is particularly important for self-collected blood, as the transport of the sample to the clinical laboratory will generally require significantly more time than routine blood samples collected by healthcare professionals, and under less controlled circumstances. METHODS: Three additional blood collection tubes (coagulation tubes) were collected from nine patients; one was processed immediately, the second and third were processed after 48 h of storage at 20 °C and 37 °C, respectively. The collected serum was stored at -20 °C and samples collected from individual patients were analyzed in the same analytical run for 18 routine chemistry analytes and the tumor markers PSA and CEA. The recoveries obtained after delayed processing were quantified and the quality of the sample for each analyte was determined using the analytical performance specifications based on biological variation. RESULTS: For each analyte, the quality level of samples with delayed processing was determined. For the CEA, PSA, CRP, creatinine, HDL-cholestrol, triglycerides and yGT the recovery was within the desirable bias requirement. Recovery for glucose, all included electrolytes, ALT and AST exceeded the minimum bias criterion. CONCLUSIONS: Several analytes including sodium, chloride, potassium, calcium, and liver enzymes were not, while others; CEA, PSA, CRP, creatinine and triglycerides, were found to be sufficiently stable in coagulated blood, when processed with a delay of 48 h.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Laboratory Medicine, The Netherlands Cancer Institute, Amsterdam, the Netherlands.
- Department of Laboratory Medicine, The Netherlands Cancer Institute, Amsterdam, the Netherlands; Self Safe Sure Blood Collections B.V., Amsterdam, the Netherlands. Electronic address: h.v.rossum@nki.nl.
Zitieren
APA
Roelofs, M., Ramkisoensing, K., Even, R., & van Rossum, H. H. (2025). Pre-processing stability of routine clinical chemistry analytes in a clotting tube; investigating the (un)suitability for at-home sample collection. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2024.120035
Vancouver
Roelofs M, Ramkisoensing K, Even R, van Rossum HH. Pre-processing stability of routine clinical chemistry analytes in a clotting tube; investigating the (un)suitability for at-home sample collection. Clinica Chimica Acta. 2025. doi:10.1016/j.cca.2024.120035
BibTeX
@article{Roelofs2025,
author = {Roelofs, Maaike and Ramkisoensing, Kalpana and Even, Rixt and van Rossum, Huub H},
title = {Pre-processing stability of routine clinical chemistry analytes in a clotting tube; investigating the (un)suitability for at-home sample collection},
journal = {Clinica Chimica Acta},
year = {2025},
doi = {10.1016/j.cca.2024.120035}
}
EUVIMED