Comparison of three blood collection tubes for 16 biochemical analytes and stability assessment of selected analytes: VACUETTE ® CAT serum Sep clot activator tube, VACUETTE ® LH lithium heparin Sep tube, and VACUETTE ® CAT serum fast separator tube
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · 2025
DOI: 10.1177/00045632251329272 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2025. Verfasst von Jong Do Seo und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Konkuk University Medical Center, Seoul, Korea. Hauptthemen laut MEDLINE: Blood Specimen Collection, Heparin, Blood Chemical Analysis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
Background
Analytical performance of VACUETTE® CAT Serum Fast Separator Tube (SFT; Greiner Bio-One, Austria), recently developed quick-clotting serum separator, was evaluated for correlation and stability, comparing with VACUETTE® CAT Serum Sep Clot Activator Tube (SST; Greiner Bio-One) and VACUETTE® LH Lithium Heparin Sep Tube (LiHep Tube; Greiner Bio-One).
Method
For 107 paired samples, 16 analytes (glucose, potassium, LDH, CRP, creatinine, AST, ALT, ALP, GGT, AFP, PSA, TSH, free T4, iPTH, CK-MB, and cardiac troponin I[cTnI]) were measured. Correlations were assessed using Passing–Bablok regression and paired t-tests. Differences were evaluated by comparing the mean percentage difference and estimated difference at medical decision limits (MDLs), to the acceptable desirable difference. For six analytes – glucose, potassium, LDH, AST, iPTH, and cTnI – known for different stabilities between sample types, stability was evaluated by comparing changes over time with desirable differences.
Results
Across the evaluated range, SFT showed clinically comparable differences to SST, except for CK-MB which showed significant positive bias. Plasma exhibited unacceptable biases: negative for potassium and positive for LDH and CK-MB. Estimated differences at MDLs were acceptable in SFT except for potassium and CK-MB, while plasma showed unacceptable differences in potassium, LDH, creatinine, and CK-MB. LiHep Tube showed reduced stability than SST for all analytes except for iPTH, impairing retest reliability. SFT showed comparable stability except for LDH and iPTH, which showed slightly shortened stability.
Conclusions
The SFT demonstrated high correlation and comparable stability to SST, making it a suitable replacement for the LiHep Tube, as an alternative to SST for rapid testing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Laboratory Medicine, Konkuk University Medical Center, Seoul, Korea.
- Department of Cardiovascular Medicine, Konkuk University School of Medicine, Seoul, Korea.
- Department of Laboratory Medicine, Konkuk University School of Medicine, Seoul, Korea.
ORCID-Profile: Jong Do Seo, Changhee Ha
Zitieren
APA
Seo, J. D., Lee, Y. J., Ha, C., Choi, J. H., Shin, S. H., Han, H. Y., Kim, H. J., Kim, S. H., Kim, B. S., Kim, H., Moon, H. W., Hur, M., & Yun, Y. M. (2025). Comparison of three blood collection tubes for 16 biochemical analytes and stability assessment of selected analytes: VACUETTE ® CAT serum Sep clot activator tube, VACUETTE ® LH lithium heparin Sep tube, and VACUETTE ® CAT serum fast separator tube. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/00045632251329272
Vancouver
Seo JD, Lee YJ, Ha C, Choi JH, Shin SH, Han HY, et al. Comparison of three blood collection tubes for 16 biochemical analytes and stability assessment of selected analytes: VACUETTE ® CAT serum Sep clot activator tube, VACUETTE ® LH lithium heparin Sep tube, and VACUETTE ® CAT serum fast separator tube. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. 2025. doi:10.1177/00045632251329272
BibTeX
@article{Seo2025,
author = {Seo, Jong Do and Lee, Yeon Jae and Ha, Changhee and Choi, Ju Hee and Shin, Seon-Hyeon and Han, Hye Young and Kim, Hyun-Joong and Kim, Sung Hea and Kim, Bum Sung and Kim, Hanah and Moon, Hee-Won and Hur, Mina and Yun, Yeo-Min},
title = {Comparison of three blood collection tubes for 16 biochemical analytes and stability assessment of selected analytes: VACUETTE ® CAT serum Sep clot activator tube, VACUETTE ® LH lithium heparin Sep tube, and VACUETTE ® CAT serum fast separator tube},
journal = {Annals of Clinical Biochemistry: International Journal of Laboratory Medicine},
year = {2025},
doi = {10.1177/00045632251329272}
}
EUVIMED