Integration of single-click, AI-based brachytherapy auto-planning for cervical cancer within a treatment planning system
Brachytherapy · 2026-01 · 25 (1) · 206-213
DOI: 10.1016/j.brachy.2025.08.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Brachytherapy, 2026-01. Verfasst von Ryan Truong und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, CA. Hauptthemen laut MEDLINE: Brachytherapy, Radiotherapy Planning, Computer-Assisted, Uterine Cervical Neoplasms, Artificial Intelligence. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, Varian Medical Systems Inc, National Institutes of Health.
Abstract (Originalsprache)
PURPOSE: Previous work developed an automated cervical brachytherapy treatment planning pipeline consisting of a U-Net dose prediction model and dwell time optimizer. While this method can produce clinically acceptable plans, it relies on time-consuming, manual export and import of DICOM data. This study proposes to increase efficiency by combining scripts into an all-in-one tool that can be used directly within the BrachyVision treatment planning system, producing automated plans in a single click. MATERIALS AND METHODS: We developed an AI-based planning tool through four main tasks; data retrieval, model inference, dwell time optimization, and auto-plan import. First, a C# plug-in interacts with the currently open patient in BrachyVision. Next, for data retrieval, model inference, and dwell time optimization, a Python executable operates on the data before the optimized dwell times are copied back into the open plan in BrachyVision. The script was tested on 28 brachytherapy plans spanning 7 applicator types, and auto-plans were compared to clinical plans using mean absolute error (MAE) in voxel-based 3D dose and dwell times. RESULTS: The average (± standard deviation) MAE in 3D dose and dwell times were 3.8 ± 0.7% (normalized to the prescribed dose) and 10.3 ± 7.4 s (2.1 ± 0.9% of the total plan dwell time), respectively. The average runtime of the script was 3.5 ± 1.2 minutes. CONCLUSIONS: We developed a script that enables efficient, streamlined auto-planning directly within BrachyVision. After contouring and digitization are performed, the script can be run to produce high-quality, customized plans with a single button-click in a few minutes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, CA.
- Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, CA. Electronic address: lcmoore@health.ucsd.edu.
- Department of Surgery, University of California San Diego, La Jolla, CA.
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA.
Förderung
- NCI NIH HHS
- Varian Medical Systems Inc
- National Institutes of Health
- National Institutes of Health National Cancer Institute
Zitieren
APA
Truong, R., Moore, L. C., Mitra, A., Kallis, K., Kisling, K., Vasconcelos, N., & Meyers, S. M. (2026). Integration of single-click, AI-based brachytherapy auto-planning for cervical cancer within a treatment planning system. Brachytherapy, 25(1), 206-213. https://doi.org/10.1016/j.brachy.2025.08.004
Vancouver
Truong R, Moore LC, Mitra A, Kallis K, Kisling K, Vasconcelos N, et al. Integration of single-click, AI-based brachytherapy auto-planning for cervical cancer within a treatment planning system. Brachytherapy. 2026;25(1):206-213. doi:10.1016/j.brachy.2025.08.004
BibTeX
@article{Truong2026,
author = {Truong, Ryan and Moore, Lance C and Mitra, Aranyo and Kallis, Karoline and Kisling, Kelly and Vasconcelos, Nuno and Meyers, Sandra M},
title = {Integration of single-click, AI-based brachytherapy auto-planning for cervical cancer within a treatment planning system},
journal = {Brachytherapy},
year = {2026},
volume = {25},
number = {1},
pages = {206--213},
doi = {10.1016/j.brachy.2025.08.004}
}
EUVIMED