Rule-based AI automated adaptive treatment planning for image guided cervical cancer brachytherapy
Brachytherapy · 2025
DOI: 10.1016/j.brachy.2025.05.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Brachytherapy, 2025. Verfasst von Linda Rossi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands. Electronic address: l.rossi…. Hauptthemen laut MEDLINE: Brachytherapy, Uterine Cervical Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Image-Guided. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND AND PURPOSE: A rule-based AI system for automated adaptive treatment planning for image guided adaptive brachytherapy (IGABT) of locally advanced cervical cancer (LACC) was developed at Erasmus MC, and internally and externally validated by Erasmus MC and Tata Memorial Centre (TMC), respectively. MATERIALS AND METHODS: The BiCycle system generates automated plans with adapted requirements for each fraction, considering previously delivered external beam radiotherapy (EBRT) and BT doses, according EMBRACE-II protocol. It optimizes dosimetric parameters and loading patterns for available radioactive source positions. The system's effectiveness was validated by comparing automatically generated plans (AUTO) with manually generated, clinically delivered plans (MANUAL) of (1) dosimetry parameters and loading pattern visual inspection of 15 previously treated patients, for internal validation and (2) dosimetry and qualitative comparison by two TMC physicians of 20 previously treated patients, for external validation. RESULTS: With comparable target doses, AUTO plans had reduced D2cm3 (expressed as EBRT + BT total EQD2α/β) for bladder, rectum, sigmoid and bowel compared to MANUAL plans with average gains of 5.3 Gy, 2.4 Gy, 2.5 Gy and 2.7 Gy, respectively, for internal validation, and of 3.6 Gy, 4.3 Gy, 1.9 Gy and 1.1 Gy, respectively, for external validation. The two TMC physicians preferred the AUTO plans in 76.3% and 75.0% of comparisons. CONCLUSION: A novel AI-system for fully automated IGABT treatment planning for LACC allowed high-quality plan optimization in on average 1.6 min. AUTO plans were considered superior in quality compared to MANUAL plans in both internal and external validations, even without optimizing the system's configuration for the external center.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands. Electronic address: l.rossi@erasmusmc.nl.
- Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands.
- Department of Radiation Oncology and Medical Physics, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, Navi Mumbai, Maharashtra, India.
- Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, Maharashtra, India.
Zitieren
APA
Rossi, L., Bijman, R., Chopra, S., Mittal, P., Panda, S., Westerveld, H., Christianen, M., Kolkman-Deurloo, I. K., Breedveld, S., Nout, R., & Heijmen, B. (2025). Rule-based AI automated adaptive treatment planning for image guided cervical cancer brachytherapy. Brachytherapy. https://doi.org/10.1016/j.brachy.2025.05.007
Vancouver
Rossi L, Bijman R, Chopra S, Mittal P, Panda S, Westerveld H, et al. Rule-based AI automated adaptive treatment planning for image guided cervical cancer brachytherapy. Brachytherapy. 2025. doi:10.1016/j.brachy.2025.05.007
BibTeX
@article{Rossi2025,
author = {Rossi, Linda and Bijman, Rik and Chopra, Supriya and Mittal, Prachi and Panda, Subhajit and Westerveld, Henrike and Christianen, Miranda and Kolkman-Deurloo, Inger-Karine and Breedveld, Sebastiaan and Nout, Remi and Heijmen, Ben},
title = {Rule-based AI automated adaptive treatment planning for image guided cervical cancer brachytherapy},