Toward a deep learning-based magnetic resonance imaging only workflow for postimplant dosimetry in I-125 seed brachytherapy for prostate cancer
Brachytherapy · 2024
DOI: 10.1016/j.brachy.2023.09.009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Brachytherapy, 2024. Verfasst von Johanna Grigo und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany; Comprehensive C…. Hauptthemen laut MEDLINE: Brachytherapy, Deep Learning, Prostatic Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Friedrich-Alexander-Universität Erlangen-Nürnberg.
Abstract (Originalsprache)
BACKGROUND AND PURPOSE: The current standard imaging-technique for creating postplans in seed prostate brachytherapy is computed tomography (CT), that is associated with additional radiation exposure and poor soft tissue contrast. To establish a magnetic resonance imaging (MRI) only workflow combining improved tissue contrast and high seed detectability, a deep learning-approach for automatic seed segmentation on MRI-scans was developed. MATERIAL AND METHODS: Patients treated with I-125 seed brachytherapy received a postplan-CT and a 1.5 T MRI-scan on nominal day 30 after implantation. For MRI-based seed visualization, DIXON-sequences were acquired and deep learning-based quantitative susceptibility maps (QSM) were generated from 3D-gradient-echo-sequences from 20 patients. Seed segmentations created on CT served as ground truth. For automatic seed segmentation on MRI, a 3D nnU-net model was trained using QSM and DIXON, both solely and combined. RESULTS: Of the implanted seeds 94.8 ± 2.4% were detected with deep learning automatic segmentation entrained on both QSM and DIXON data. Models trained on the individual sequence data-sets performed worse with detection rates of 87.5 ± 2.6% or 88.6 ± 7.5% for QSM and DIXON respectively. The seed centers identified on CT versus QSM and DIXON were on average 1.8 ± 1.3 mm apart. Postimplant dosimetry for evaluation of positioning inaccuracies revealed only small variations of up to 0.4 ± 4.26 Gy in D90 (dose 90% of the prostate receives) between the standard CT-approach and our MRI-only workflow. CONCLUSION: The proposed deep learning-based MRI-only workflow provided a promisingly accurate and robust seed localization and thus has the potential to compete with current state-of-the-art CT-based postimplant dosimetry in the future.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany; Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany. Electronic…
- Department of Radiation Oncology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany; Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany.
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Förderung
- Friedrich-Alexander-Universität Erlangen-Nürnberg
Zitieren
APA
Grigo, J., Karius, A., Hanspach, J., Mücke, L., Laun, F. B., Huang, Y., Strnad, V., Fietkau, R., Bert, C., & Putz, F. (2024). Toward a deep learning-based magnetic resonance imaging only workflow for postimplant dosimetry in I-125 seed brachytherapy for prostate cancer. Brachytherapy. https://doi.org/10.1016/j.brachy.2023.09.009
Vancouver
Grigo J, Karius A, Hanspach J, Mücke L, Laun FB, Huang Y, et al. Toward a deep learning-based magnetic resonance imaging only workflow for postimplant dosimetry in I-125 seed brachytherapy for prostate cancer. Brachytherapy. 2024. doi:10.1016/j.brachy.2023.09.009
BibTeX
@article{Grigo2024,
author = {Grigo, Johanna and Karius, Andre and Hanspach, Jannis and Mücke, Lion and Laun, Frederik B and Huang, Yixing and Strnad, Vratislav and Fietkau, Rainer and Bert, Christoph and Putz, Florian},
title = {Toward a deep learning-based magnetic resonance imaging only workflow for postimplant dosimetry in I-125 seed brachytherapy for prostate cancer},
journal = {Brachytherapy},
year = {2024},
doi = {10.1016/j.brachy.2023.09.009}
}
EUVIMED