EUVIMEDEUVIMED entdecken
Crossref

Dosimetric and workflow impact of synthetic-MRI use in prostate high-dose-rate brachytherapy

Alexander R Podgorsak, Bhanu P Venkatesulu, Mohammad Abuhamad, Matthew M Harkenrider, Abhishek A Solanki, John C Roeske, Hyejoo Kang

Brachytherapy · 2023

DOI: 10.1016/j.brachy.2023.05.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brachytherapy, 2023. Verfasst von Alexander R Podgorsak und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University Chicago, Chicago, IL. Electronic ad…. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Brachytherapy. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 53 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Target and organ delineation during prostate high-dose-rate (HDR) brachytherapy treatment planning can be improved by acquiring both a postimplant CT and MRI. However, this leads to a longer treatment delivery workflow and may introduce uncertainties due to anatomical motion between scans. We investigated the dosimetric and workflow impact of MRI synthesized from CT for prostate HDR brachytherapy. METHODS AND MATERIALS: Seventy-eight CT and T2-weighted MRI datasets from patients treated with prostate HDR brachytherapy at our institution were retrospectively collected to train and validate our deep-learning-based image-synthesis method. Synthetic MRI was assessed against real MRI using the dice similarity coefficient (DSC) between prostate contours drawn using both image sets. The DSC between the same observer's synthetic and real MRI prostate contours was compared with the DSC between two different observers' real MRI prostate contours. New treatment plans were generated targeting the synthetic MRI-defined prostate and compared with the clinically delivered plans using target coverage and dose to critical organs. RESULTS: Variability between the same observer's prostate contours from synthetic and real MRI was not significantly different from the variability between different observer's prostate contours on real MRI. Synthetic MRI-planned target coverage was not significantly different from that of the clinically delivered plans. There were no increases above organ institutional dose constraints in the synthetic MRI plans. CONCLUSIONS: We developed and validated a method for synthesizing MRI from CT for prostate HDR brachytherapy treatment planning. Synthetic MRI use may lead to a workflow advantage and removal of CT-to-MRI registration uncertainty without loss of information needed for target delineation and treatment planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prostatic NeoplasmsBrachytherapyMaleHumansProstateWorkflowRetrospective StudiesRadiotherapy DosageRadiotherapy Planning, Computer-AssistedMagnetic Resonance Imaging

Stichwörter der Autor:innen

Artificial intelligenceMachine learningProstate interstitial brachytherapySynthetic MRI

Autor:innen und Institutionen

  • Department of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University Chicago, Chicago, IL. Electronic address: alexander.podgorsak@luhs.org.
  • Department of Radiation Oncology, Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University Chicago, Chicago, IL.
  • Department of Computer Science, Loyola University Chicago, Chicago, IL.

Zitieren

APA

Podgorsak, A. R., Venkatesulu, B. P., Abuhamad, M., Harkenrider, M. M., Solanki, A. A., Roeske, J. C., & Kang, H. (2023). Dosimetric and workflow impact of synthetic-MRI use in prostate high-dose-rate brachytherapy. Brachytherapy. https://doi.org/10.1016/j.brachy.2023.05.005

Vancouver

Podgorsak AR, Venkatesulu BP, Abuhamad M, Harkenrider MM, Solanki AA, Roeske JC, et al. Dosimetric and workflow impact of synthetic-MRI use in prostate high-dose-rate brachytherapy. Brachytherapy. 2023. doi:10.1016/j.brachy.2023.05.005

BibTeX
@article{Podgorsak2023,
  author = {Podgorsak, Alexander R and Venkatesulu, Bhanu P and Abuhamad, Mohammad and Harkenrider, Matthew M and Solanki, Abhishek A and Roeske, John C and Kang, Hyejoo},
  title = {Dosimetric and workflow impact of synthetic-MRI use in prostate high-dose-rate brachytherapy},
  journal = {Brachytherapy},
  year = {2023},
  doi = {10.1016/j.brachy.2023.05.005}
}
Kostenlos starten →