Deep learning auto‐contouring of target and organs‐at‐risk on post‐catheter implant CT images for prostate HDR brachytherapy
Journal of Applied Clinical Medical Physics · 2026
DOI: 10.1002/acm2.70748 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Eric M Wallat und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Brachytherapy, Deep Learning, Prostatic Neoplasms, Organs at Risk. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Accurate delineation of the prostate and surrounding organs‐at‐risk (OARs) is essential for HDR prostate brachytherapy. Manual contouring on post‐catheter CT images is time‐consuming and prone to variability due to artifacts and anatomical deformation from the implanted brachytherapy catheters.
Purpose
To develop and validate a 3D deep learning autosegmentation model for prostate and OAR contouring on post‐catheter CT images for prostate brachytherapy planning.
Methods
A self‐configuring U‐Net architecture (nnU‐Net) was trained on 206 HDR prostate brachytherapy cases and tested on an additional 36 patients. Structures included prostate PTV, bladder, rectum, and urethra identified from a Foley catheter. Performance was evaluated against a commercially available model using geometric (Dice coefficient (DSC), Hausdorff distance (HD95%), average surface distance (ASD)) and dosimetric metrics (PTV V100%, bladder and rectum D1cc, urethra D0.1cc). Statistical significance was assessed using paired Wilcoxon signed‐rank tests.
Results
NnU‐Net achieved superior geometric accuracy versus the commercial model for all structures within slices containing the prostate. For prostate PTV, nnU‐Net yielded DSC = 0.91 +/− 0.04, HD95% = 3.62 +/− 2.23 mm, and ASD = 1.25 +/− 0.66 mm, compared to DSC = 0.78 +/− 0.07, HD95% = 9.52 +/− 4.73 mm, and ASD = 2.97 +/− 0.90 mm for the commercial model. Urethra segmentation was only provided by nnU‐Net (DSC = 0.84 +/− 0.09). Dosimetric differences for nnU‐Net were clinically negligible: ΔPTV V100% = −0.25 +/−2.30%, bladder ΔD1cc = 0.13 +/− 0.75 Gy, rectum ΔD1cc = 0.34 +/− 0.74 Gy, and urethra ΔD0.1cc = −0.03 +/− 0.16 Gy. Differences in PTV V100% were not significant for nnU‐Net ( p = 0.91) but significant for the commercial model ( p < 0.001).
Conclusions
A brachytherapy‐specific nnU‐Net model enables accurate autosegmentation of prostate and OARs on post‐catheter CT images, outperforming an EBRT‐trained commercial solution. Minimal dosimetric differences support clinical feasibility and potential workflow improvements in HDR prostate brachytherapy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Zitieren
APA
Wallat, E. M., Schulz, J. B., Floberg, J. M., Cooley, G., Bednarz, B. P., & Slagowski, J. M. (2026). Deep learning auto‐contouring of target and organs‐at‐risk on post‐catheter implant CT images for prostate HDR brachytherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70748
Vancouver
Wallat EM, Schulz JB, Floberg JM, Cooley G, Bednarz BP, Slagowski JM. Deep learning auto‐contouring of target and organs‐at‐risk on post‐catheter implant CT images for prostate HDR brachytherapy. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70748
BibTeX
@article{Wallat2026,
author = {Wallat, Eric M and Schulz, Joseph B and Floberg, John M and Cooley, Gregory and Bednarz, Bryan P and Slagowski, Jordan M},
title = {Deep learning auto‐contouring of target and organs‐at‐risk on post‐catheter implant CT images for prostate HDR brachytherapy},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
doi = {10.1002/acm2.70748}
}
EUVIMED