A flexible paper-based microneedle array electrochemical sensor for CEA detection in interstitial fluid at the point of care
Biosensors and Bioelectronics · 2026-11 · 312 · 119066
DOI: 10.1016/j.bios.2026.119066 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Yue Jin und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, 230027, China. Hauptthemen laut MEDLINE: Carcinoembryonic Antigen, Biosensing Techniques, Extracellular Fluid, Electrochemical Techniques. Die Arbeit nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
Carcinoembryonic antigen (CEA) detection is crucial for early cancer diagnosis and prognostic monitoring. However, traditional CEA detection is mainly based on blood samples, which is invasive and less conducive to point-of-care testing (POCT). Therefore, in this study, we developed a flexible paper-based microneedle (MN) array electrochemical sensor, integrated with portable electronics and a mobile application, to detect CEA in interstitial fluid (ISF). The MN array was fabricated from a composite of UV-curable biocompatible resin and microcrystalline cellulose on a paper substrate impregnated with flexible UV-curable resin. The MN array was functionalized as an electrochemical sensor to detect CEA by modification with conductive ink, rGO/Thi/AuNPs nanocomposites and anti-CEA antibodies. The performance of the MN array electrochemical sensor was validated through in vitro and in vivo experiments, and the sensor demonstrated high sensitivity, good selectivity, broad linear ranges, robust stability, and strong concordance with reference methods. This study provides a new tool for CEA monitoring and offers new insights into the development of minimally invasive biomarker detection devices for POCT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, 230027, China.
- The Second People's Hospital of Hefei, Hefei, Anhui, 230011, China.
- Hefei Institute of Technology, Hefei, Anhui, 238076, China.
- Medical College, Guizhou University, Guiyang, Guizhou, 550025, China.
- Department of Burns, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230022, China.
- Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, 230027, China. Electronic address: bqiu@ustc.edu.cn.
Förderung
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Jin, Y., Holman, J. B., Yu, Q., Chen, X., Sun, S., Hu, Y., Chen, J., Qiu, B., Ding, W., & Li, C. (2026). A flexible paper-based microneedle array electrochemical sensor for CEA detection in interstitial fluid at the point of care. Biosensors and Bioelectronics, 312, 119066. https://doi.org/10.1016/j.bios.2026.119066
Vancouver
Jin Y, Holman JB, Yu Q, Chen X, Sun S, Hu Y, et al. A flexible paper-based microneedle array electrochemical sensor for CEA detection in interstitial fluid at the point of care. Biosensors and Bioelectronics. 2026;312:119066. doi:10.1016/j.bios.2026.119066
BibTeX
@article{Jin2026,
author = {Jin, Yue and Holman, Joseph Benjamin and Yu, Qigui and Chen, Xiangyu and Sun, Shuohui and Hu, Yi and Chen, Jie and Qiu, Bensheng and Ding, Weiping and Li, Chengpan},
title = {A flexible paper-based microneedle array electrochemical sensor for CEA detection in interstitial fluid at the point of care},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {312},
pages = {119066},
doi = {10.1016/j.bios.2026.119066}
}
EUVIMED