Engineering a self-sufficient ECL system: Oxygen-vacancy-driven O2 generation and nanozyme confinement for bioanalysis

Nastaran Arab, Morteza Hosseini, Guobao Xu, Hodjattallah Rabbani

Biosensors and Bioelectronics · 2026-06 · 301 · 118491

DOI: 10.1016/j.bios.2026.118491 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-06. Verfasst von Nastaran Arab und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nanobiosensors Lab, Department of Nanobiotechnology and Biomimetics School of Life Science Engineering College of Interdisciplinary Science and Techn…. Hauptthemen laut MEDLINE: Biosensing Techniques, Oxygen, Carcinoembryonic Antigen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: Chinese Academy of Sciences, University of Tehran, Iran National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oxygen vacancies in nonnoble metal nanocatalysts, while extensively explored for oxygen evolution reactions (OER), have rarely been harnessed for electrochemiluminescence (ECL) immunosensing. In this work, we report the rational construction of a novel Fe-Co-CeO2@Ti3C2(OH)2 heterostructure, incorporating Fe-Co dual active sites and abundant oxygen vacancies, through an energy-free co-deposition strategy for efficient OER under near-neutral conditions. Notably, Fe-Co-CeO2@Ti3C2(OH)2 heterostructure not only enhances OER activity but also the oxygen vacancy enriched CeO2 nanoparticles of the heterostructure facilitate superoxide radical (O2•-) generation within the luminol system in the absence of conventional co-reactants (e.g., H2O2 or dissolved O2). In addition, FeCo-NH2-BDC was employed as a signaling probe, whose intrinsic oxidase mimetic activity catalyzes O2 to O2•-, further amplifying the ECL response. By integrating these multiple amplification pathways, we developed a novel biosensing platform for the highly sensitive detection of carcinoembryonic antigen (CEA). The ECL signals were quantified using both a photomultiplier tube (PMT) and a smartphone based visual readout, achieving linear response ranges of 10 pg mL-1-25 ng mL-1 (LOD: 6.35 pg mL-1) and 35 pg mL-1-50 ng mL-1 (LOD: 12.42 pg mL-1), respectively. This work provides a powerful approach for high performance bioanalysis and offers a promising avenue toward the development of ultrasensitive, user friendly diagnostic devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesOxygenCarcinoembryonic AntigenLuminescent MeasurementsElectrochemical TechniquesHumansCeriumLimit of DetectionCobaltTitaniumIron

Stichwörter der Autor:innen

Cascade amplification strategyElectrochemiluminescence immunosensorOxygen evolution reactionOxygen vacancy engineeringPoint-of-care bioanalysis

Substanzen

OxygenCarcinoembryonic AntigenCeriumCobaltTitaniumceric oxideIron

Autor:innen und Institutionen

  • Nanobiosensors Lab, Department of Nanobiotechnology and Biomimetics School of Life Science Engineering College of Interdisciplinary Science and Technology, University of Tehran, Tehran, 1439817435, Iran.
  • Nanobiosensors Lab, Department of Nanobiotechnology and Biomimetics School of Life Science Engineering College of Interdisciplinary Science and Technology, University of Tehran, Tehran, 1439817435, Iran; State Key Labor…
  • State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, China; School of Applied Chemistry and Engineering, University of Science an…
  • Monoclonal Antibody Research Center, Avicenna Research Institute, ACECR, Tehran, Iran.

Förderung

  • Chinese Academy of Sciences
  • University of Tehran
  • Iran National Science Foundation

Zitieren

APA

Arab, N., Hosseini, M., Xu, G., & Rabbani, H. (2026). Engineering a self-sufficient ECL system: Oxygen-vacancy-driven O2 generation and nanozyme confinement for bioanalysis. Biosensors and Bioelectronics, 301, 118491. https://doi.org/10.1016/j.bios.2026.118491

Vancouver

Arab N, Hosseini M, Xu G, Rabbani H. Engineering a self-sufficient ECL system: Oxygen-vacancy-driven O2 generation and nanozyme confinement for bioanalysis. Biosensors and Bioelectronics. 2026;301:118491. doi:10.1016/j.bios.2026.118491

BibTeX
@article{Arab2026,
  author = {Arab, Nastaran and Hosseini, Morteza and Xu, Guobao and Rabbani, Hodjattallah},
  title = {Engineering a self-sufficient ECL system: Oxygen-vacancy-driven O2 generation and nanozyme confinement for bioanalysis},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {301},
  pages = {118491},
  doi = {10.1016/j.bios.2026.118491}
}
Kostenlos starten →