Controlled-Release Electrochemiluminescence Biosensor with Strong Self-On Effect by a Multiple Signal Amplification Strategy for Trace Detection of Prostate-Specific Antigen
Analytical Chemistry · 2024
DOI: 10.1021/acs.analchem.4c00048 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2024. Verfasst von Ziqiu Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China. Hauptthemen laut MEDLINE: Prostate-Specific Antigen, Biosensing Techniques, Electrochemical Techniques, Luminescent Measurements. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Taishan Scholar Project of Shandong Province.
Abstract (Originalsprache)
The enhancement of sensitivity in biological analysis detection can reduce the probability of false positives of the biosensor. In this work, a novel self-on controlled-release electrochemiluminescence (CRE) biosensor was designed by multiple signal amplification and framework-enhanced stability strategies. As a result, the changes of the ECL signal were enhanced before and after the controlled-release process, achieving sensitive detection of prostate-specific antigen (PSA). Specifically, for one thing, Fe3O4@CeO2-NH2 with two paths for enhancing the generation of coreactant radicals was used as the coreaction accelerator to boost ECL performance. For another, due to the framework stability, zeolitic imidazolate framework-8-NH2 (ZIF-8-NH2) was combined with luminol to make the ECL signal more stable. Based on these strategies, the constructed CRE biosensor showed a strong self-on effect in the presence of PSA and high sensitivity in a series of tests. The detection range and limit of detection (LOD) were 5 fg/mL to 10 ng/mL and 2.8 fg/mL (S/N = 3), respectively, providing a feasible approach for clinical detection of PSA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
- Shandong Water Conservancy Vocational College, Rizhao 276826, P. R. China.
Förderung
- National Natural Science Foundation of China
- Taishan Scholar Project of Shandong Province
Zitieren
APA
Huang, Z., Zhao, L., Guo, Q., Fan, D., Ren, X., Wei, Q., & Wu, D. (2024). Controlled-Release Electrochemiluminescence Biosensor with Strong Self-On Effect by a Multiple Signal Amplification Strategy for Trace Detection of Prostate-Specific Antigen. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c00048
Vancouver
Huang Z, Zhao L, Guo Q, Fan D, Ren X, Wei Q, et al. Controlled-Release Electrochemiluminescence Biosensor with Strong Self-On Effect by a Multiple Signal Amplification Strategy for Trace Detection of Prostate-Specific Antigen. Analytical Chemistry. 2024. doi:10.1021/acs.analchem.4c00048
BibTeX
@article{Huang2024,
author = {Huang, Ziqiu and Zhao, Lu and Guo, Qingfang and Fan, Dawei and Ren, Xiang and Wei, Qin and Wu, Dan},
title = {Controlled-Release Electrochemiluminescence Biosensor with Strong Self-On Effect by a Multiple Signal Amplification Strategy for Trace Detection of Prostate-Specific Antigen},
journal = {Analytical Chemistry},
year = {2024},
doi = {10.1021/acs.analchem.4c00048}
}
EUVIMED