EUVIMEDEUVIMED entdecken
Crossref

Self-Enhanced Ratiometric ECL Strategy Based on a Dual-Emission Ce/Tb-MOF Luminophore with Spatially Resolved Coreactant Delivery for Ultrasensitive Pro-GRP Detection

Dewen Yan, Yue Zhang iD, Weiming Gong, Dan Ren, Linlin Cao, Yueyuan Li, Yueyun Li iD, Hui Liu iD, Qing Liu iD

Analytical Chemistry · 2025

DOI: 10.1021/acs.analchem.5c04144 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Dewen Yan und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China. Hauptthemen laut MEDLINE: Electrochemical Techniques, Luminescent Measurements, Metal-Organic Frameworks, Terbium. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dual-signal-output ratiometric electrochemiluminescence (ECL) platforms offer a promising solution to address the instability and inaccuracies associated with single-signal ECL detection. However, most existing ratiometric systems still rely on two independent luminophores, inevitably increasing the system complexity and compromising the detection accuracy. In this study, a bimetallic dual-ligand ECL luminophore, Ce/Tb-MOF, was synthesized via a solvothermal approach, exhibiting distinct anodic and cathodic ECL emissions from a single luminophore. To spatially regulate signal generation and avoid the complications of coreactant mixing, we designed a beacon nanostructure, TPA-β-CD@Au, that locally introduces the anodic coreactant tripropylamine (TPA) upon target binding. This enabled the implementation of a ″Reverse Regulation of Anodic/Cathodic Signals″ strategy, wherein target recognition simultaneously suppresses cathodic emission and enhances anodic emission, achieving internally calibrated signal output. Based on this mechanism, a highly sensitive ECL immunosensor was developed for the detection of Pro-gastrin-releasing peptide (Pro-GRP). The sensor exhibited excellent analytical performance, including a broad dynamic range (100 fg/mL to 100 ng/mL), a low detection limit of 52.4 fg/mL, and strong anti-interference capability. This work presents a robust and simplified ratiometric ECL platform and provides valuable insights into the rational design of multifunctional MOF-based biosensors for clinical diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrochemical TechniquesLuminescent MeasurementsMetal-Organic FrameworksTerbiumBiosensing TechniquesCeriumLuminescent AgentsHumansLimit of DetectionGold

Substanzen

Metal-Organic FrameworksTerbiumCeriumLuminescent AgentsGold

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China.
  • Zibo Central Hospital, Zibo 255036, PR China.

ORCID-Profile: Yue Zhang, Yueyun Li, Hui Liu, Qing Liu

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Shandong Province

Zitieren

APA

Yan, D., Zhang, Y., Gong, W., Ren, D., Cao, L., Li, Y., Li, Y., Liu, H., & Liu, Q. (2025). Self-Enhanced Ratiometric ECL Strategy Based on a Dual-Emission Ce/Tb-MOF Luminophore with Spatially Resolved Coreactant Delivery for Ultrasensitive Pro-GRP Detection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c04144

Vancouver

Yan D, Zhang Y, Gong W, Ren D, Cao L, Li Y, et al. Self-Enhanced Ratiometric ECL Strategy Based on a Dual-Emission Ce/Tb-MOF Luminophore with Spatially Resolved Coreactant Delivery for Ultrasensitive Pro-GRP Detection. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c04144

BibTeX
@article{Yan2025,
  author = {Yan, Dewen and Zhang, Yue and Gong, Weiming and Ren, Dan and Cao, Linlin and Li, Yueyuan and Li, Yueyun and Liu, Hui and Liu, Qing},
  title = {Self-Enhanced Ratiometric ECL Strategy Based on a Dual-Emission Ce/Tb-MOF Luminophore with Spatially Resolved Coreactant Delivery for Ultrasensitive Pro-GRP Detection},
  journal = {Analytical Chemistry},
  year = {2025},
  doi = {10.1021/acs.analchem.5c04144}
}
Kostenlos starten →