EUVIMEDEUVIMED entdecken
Crossref

A scalable, enzyme-free, multimodal wearable monitoring system with active-flux-regulated sweat extraction for on-demand metabolic assessment

Zhifu Yin, Yachuan Qu, Yang Yang, Xiang Pi, Changchao Zhang, Xiancun Meng, Guangjun Chen, You Chen, Bo Li, Junqiu Zhang, Shichao Niu, Zhiwu Han und 1 weitere

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.118660 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Zhifu Yin und 12 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Automotive Chassis Integration and Bionics, School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 1…. Hauptthemen laut MEDLINE: Sweat, Wearable Electronic Devices, Biosensing Techniques, Glucose. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, China Postdoctoral Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time, non-invasive biofluid monitoring is pivotal for precision medicine. However, conventional wearable sensing systems are constrained by their reliance on passive sampling, as well as barriers to design and fabrication. Integrating active sweat extraction with reliable enzyme-free multimodal sensing remains a critical challenge in wearable electronics. Herein, we report a wearable sweat monitoring system (WSMS) featuring a programmable metabolic flux sampling strategy, enabling precise and on-demand regulation of perspiration rates. By synergizing active thermal induction with microfluidic quantitative transport, the WSMS achieves controlled sweat rates in the range of 0.1-4 μL min-1·cm-2, with a maximum inducted sweat flux of 6.3 μL min-1·cm-2. This active sampling module is integrated with an enzyme-free electrochemical sensor array for the simultaneous detection of glucose, uric acid, and pH, exhibiting superior detection limits of 6.79 μM, 0.16 μM, and 1.3 pH units, respectively. More importantly, we demonstrate a laser-engraving manufacturing process capable of fabricating large-area sensor arrays (6 m × 0.5 m, ∼1340 units) within 4 h, bridging the gap to commercial scalability. Human subjects validation confirms the ability of the WSMS to accurately track sweat metabolites in both sedentary and exercise states. This work establishes a scalable, active-sensing paradigm that overcomes the limitations of passive environmental triggers, paving the way for non-invasive health monitoring and early diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SweatWearable Electronic DevicesBiosensing TechniquesGlucoseUric AcidHumansEquipment DesignHydrogen-Ion ConcentrationElectrochemical TechniquesLimit of DetectionMonitoring, Physiologic

Stichwörter der Autor:innen

Active flux regulationEnzyme-freeOn-demand metabolic assessmentSweat sensingWearable monitoring system

Substanzen

GlucoseUric Acid

Autor:innen und Institutionen

  • National Key Laboratory of Automotive Chassis Integration and Bionics, School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130022, China; Key Laboratory of Bionic Engineering, Ministry of Educat…
  • National Key Laboratory of Automotive Chassis Integration and Bionics, School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130022, China.
  • Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, Jilin, 130022, China.
  • Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, Jilin, 130022, China. Electronic address: changchaozhang@jlu.edu.cn.
  • Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, Jilin, 130022, China. Electronic address: boli@jlu.edu.cn.
  • Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun, Jilin, 130022, China; Institute of Structured and Architected Materials, Liaoning Academy of Materials, Shenyang, 110167, China.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Shandong Province
  • China Postdoctoral Science Foundation

Zitieren

APA

Yin, Z., Qu, Y., Yang, Y., Pi, X., Zhang, C., Meng, X., Chen, G., Chen, Y., Li, B., Zhang, J., Niu, S., Han, Z., & Ren, L. (2026). A scalable, enzyme-free, multimodal wearable monitoring system with active-flux-regulated sweat extraction for on-demand metabolic assessment. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118660

Vancouver

Yin Z, Qu Y, Yang Y, Pi X, Zhang C, Meng X, et al. A scalable, enzyme-free, multimodal wearable monitoring system with active-flux-regulated sweat extraction for on-demand metabolic assessment. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118660

BibTeX
@article{Yin2026,
  author = {Yin, Zhifu and Qu, Yachuan and Yang, Yang and Pi, Xiang and Zhang, Changchao and Meng, Xiancun and Chen, Guangjun and Chen, You and Li, Bo and Zhang, Junqiu and Niu, Shichao and Han, Zhiwu and Ren, Luquan},
  title = {A scalable, enzyme-free, multimodal wearable monitoring system with active-flux-regulated sweat extraction for on-demand metabolic assessment},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.118660}
}
Kostenlos starten →