EUVIMEDEUVIMED entdecken
Crossref

Wearable 3D-printed solid microneedle voltammetric sensors based on nanostructured gold for uric acid monitoring

Marc Parrilla, Nathalie Claes, Celia Toyos-Rodríguez, Caroline E M K Dricot, Annemarijn Steijlen, Sarah Lebeer, Sara Bals, Karolien De Wael

Biosensors and Bioelectronics · 2025-12 · 289 · 117934

DOI: 10.1016/j.bios.2025.117934 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-12. Verfasst von Marc Parrilla und 7 weiteren Autor:innen. Beteiligte Einrichtung: Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium; NANOlight Cent…. Hauptthemen laut MEDLINE: Biosensing Techniques, Uric Acid, Wearable Electronic Devices, Nanostructures. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 63 Literaturangaben. Gefördert von: Nederlandse Organisatie voor Wetenschappelijk Onderzoek, Fonds De La Recherche Scientifique - FNRS, European Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microneedle-based electrochemical sensors (MES) are developed as interface systems between the sensor and interstitial fluid (ISF), allowing the transdermal monitoring of analytes with clinical value. However, the widespread adoption of MES platforms to enable advances in devices for health monitoring is still a challenge. Herein, we propose an affordable and versatile wearable patch based on 3D-printed microneedle arrays to facilitate the development of electrochemical sensors. A plug-in design with a three-electrode setup allows a rapid configuration as a voltammetric sensor. Sputtering is employed to fabricate microneedle array electrodes based on nanostructured gold. The material highlights the excellent electrochemical performance due to the nanostructured surface and provides antibiofouling capability against protein. The ability of the MES to penetrate porcine skin without damage is successfully demonstrated, showing a decrease in the signal of only 8.4 % after four insertions. Thereafter, the analytical characterization for uric acid (UA) is completed in buffer solution, protein-enriched solution, emulated ISF, and in an ex vivo setup (slope 9.2 nA μM-1), showing remarkable performance within the physiological range of UA (150-500 μM) and excellent reversibility while pierced in porcine skin (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesUric AcidWearable Electronic DevicesNanostructuresGoldAnimalsSwinePrinting, Three-DimensionalNeedlesHumansElectrochemical TechniquesSkinEquipment Design

Stichwörter der Autor:innen

3D printingHealth monitoringMicroneedle sensorNanostructured goldUric acidWearable electrochemical sensor

Substanzen

Uric AcidGold

Autor:innen und Institutionen

  • Antwerp Engineering, Photoelectrochemistry and Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium; NANOlight Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010,…
  • NANOlight Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010, Antwerp, Belgium; Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgiu…
  • Department of Bioscience Engineering, Laboratory of Applied Microbiology and Biotechnology, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium.
  • Department of Bioscience Engineering, Laboratory of Applied Microbiology and Biotechnology, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium; U-MaMi Center of Excellence, University of Antwerp, Groen…

Förderung

  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek
  • Fonds De La Recherche Scientifique - FNRS
  • European Research Council
  • Research Foundation Flanders

Zitieren

APA

Parrilla, M., Claes, N., Toyos-Rodríguez, C., Dricot, C. E. M. K., Steijlen, A., Lebeer, S., Bals, S., & De Wael, K. (2025). Wearable 3D-printed solid microneedle voltammetric sensors based on nanostructured gold for uric acid monitoring. Biosensors and Bioelectronics, 289, 117934. https://doi.org/10.1016/j.bios.2025.117934

Vancouver

Parrilla M, Claes N, Toyos-Rodríguez C, Dricot CEMK, Steijlen A, Lebeer S, et al. Wearable 3D-printed solid microneedle voltammetric sensors based on nanostructured gold for uric acid monitoring. Biosensors and Bioelectronics. 2025;289:117934. doi:10.1016/j.bios.2025.117934

BibTeX
@article{Parrilla2025,
  author = {Parrilla, Marc and Claes, Nathalie and Toyos-Rodríguez, Celia and Dricot, Caroline E M K and Steijlen, Annemarijn and Lebeer, Sarah and Bals, Sara and De Wael, Karolien},
  title = {Wearable 3D-printed solid microneedle voltammetric sensors based on nanostructured gold for uric acid monitoring},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  volume = {289},
  pages = {117934},
  doi = {10.1016/j.bios.2025.117934}
}
Kostenlos starten →