EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Ti3C2 MXene@TiO2/Co2.7Ni0.3O4 Z-scheme heterojunction as a photoelectrochemical sensing platform for H2O2 from Hela cell mitochondria

Bingjie Li, Zhenhua Ren, Xiujuan Zhang, Xinyao Zhu, Shuxian Qin, Xiaoqiang Liu, Danny K Y Wong

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2025.118034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Bingjie Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Henan Joint International Research Laboratory of Environmental Pollution Control Materials, College of Chemistry and Molecular Sciences, Henan Univer…. Hauptthemen laut MEDLINE: Titanium, Biosensing Techniques, Mitochondria, Electrochemical Techniques. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Henan University, International Science and Technology Cooperation Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, we have constructed a Ti3C2 MXene@TiO2/Co2.7Ni0.3O4 Z-type heterojunction with excellent conductivity and efficient electron transport (23 Ω charge transfer resistance, 0.79 electron transfer coefficient, and 0.29 s-1 heterogeneous electron transfer constant, based on the redox marker [Fe(CN)6]4-), which have all contributed to effectively minimising recombination of photogenerated electrons and holes, making it a superior electrode material for developing a photoelectrochemical sensor. Experimentally, low-temperature annealing was exploited to partially oxidise Ti3C2 to TiO2 to establish an intimate contact between them, before being loaded on a Co2.7Ni0.3O4 nanowire array to form a Ti3C2 MXene@TiO2/Co2.7Ni0.3O4 heterojunction. After microscopically and spectroscopically characterising the material, electrochemical studies demonstrated matching conduction band voltage of Co2.7Ni0.3O4 (0.66 eV) and valence band voltage of TiO2 (-0.4 eV) that facilitate electron transport. The results have allowed us to propose a detection mechanism for H2O2 at the photoelectrochemical sensor. The photoelectrochemical sensor was then applied to detecting H2O2 enzymatically converted by superoxide dismutase from superoxide radicals released in mitochondria extracted from cancerous HeLa cells. In this respect, a 0.05-50,000 nM linear range, a 5.93 μA sensitivity, and a 0.03 nM H2O2 limit of detection were accomplished.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumBiosensing TechniquesMitochondriaElectrochemical TechniquesHydrogen PeroxideHumansHeLa CellsCobaltNanowiresNitritesTransition Elements

Stichwörter der Autor:innen

A Ti(3)C(2)@TiO(2)/Co(2.7)Ni(0.3)O(4) Z-type heterojunctionH(2)O(2) monitoringMitochondriaPhotoelectrochemical sensor

Substanzen

Titaniumtitanium dioxideHydrogen PeroxideCobalttitanium carbideMXeneNitritesTransition Elements

Autor:innen und Institutionen

  • Henan Joint International Research Laboratory of Environmental Pollution Control Materials, College of Chemistry and Molecular Sciences, Henan University, Kaifeng, Henan Province, 475004, PR China.
  • Henan Joint International Research Laboratory of Environmental Pollution Control Materials, College of Chemistry and Molecular Sciences, Henan University, Kaifeng, Henan Province, 475004, PR China. Electronic address: l…
  • Department of Applied BioSciences, Macquarie University, Sydney, NSW, 2109, Australia. Electronic address: Danny.Wong@mq.edu.au.

Förderung

  • National Natural Science Foundation of China
  • Henan University
  • International Science and Technology Cooperation Programme

Zitieren

APA

Li, B., Ren, Z., Zhang, X., Zhu, X., Qin, S., Liu, X., & Wong, D. K. Y. (2026). A Ti3C2 MXene@TiO2/Co2.7Ni0.3O4 Z-scheme heterojunction as a photoelectrochemical sensing platform for H2O2 from Hela cell mitochondria. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118034

Vancouver

Li B, Ren Z, Zhang X, Zhu X, Qin S, Liu X, et al. A Ti3C2 MXene@TiO2/Co2.7Ni0.3O4 Z-scheme heterojunction as a photoelectrochemical sensing platform for H2O2 from Hela cell mitochondria. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118034

BibTeX
@article{Li2026,
  author = {Li, Bingjie and Ren, Zhenhua and Zhang, Xiujuan and Zhu, Xinyao and Qin, Shuxian and Liu, Xiaoqiang and Wong, Danny K Y},
  title = {A Ti3C2 MXene@TiO2/Co2.7Ni0.3O4 Z-scheme heterojunction as a photoelectrochemical sensing platform for H2O2 from Hela cell mitochondria},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2025.118034}
}
Kostenlos starten →