Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Ehsan Dezhakam und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran. Hauptthemen laut MEDLINE: Biosensing Techniques, Proteoglycans, Extracellular Vesicles, Myocardial Infarction. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 60 Literaturangaben. Gefördert von: Tabriz University of Medical Sciences, Stem Cell Research Center, Tabriz University of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Myocardial infarction (MI) is the predominant cause of death worldwide. In recent years, attempts have been gathered to find valid biomarkers for early-stage detection, and monitoring the ischemic changes within the myocardium. The elevation of angiogenesis-related factors such as endocan has been documented in several ischemic conditions. Extracellular vesicles (EVs) are valid nano-sized platforms to harbor several biomarkers such as pro-angiogenesis factors after the exposure of cells to hypoxia. Collected EVs from normal and MI samples were subjected to electrochemical sensors decorated with capture element monoclonal CD63 antibody. Using a sandwich approach, endocan levels were simultaneously examined in isolated EVs. In a complementary analysis, the levels of endocan in EVs from hypoxic and normoxic human endothelial cells (HUVECs) were also measured after being exposed to 10 μM CoCl2. It was shown that hypoxia can increase EV endocan levels compared to the normoxic EV counterparts (p < 0.05). Monitoring serum EVs revealed the elevation of EV endocan levels in MI patients compared to healthy individuals' EV samples (p < 0.05). The current data confirmed the existence of endocan in EVs under normoxic and hypoxic conditions and these levels increased under ischemic conditions. Here, we showed the eligibility of Au-perovskite-based biosensor for efficient monitoring of angiogenesis response via measuring EV endocan levels in both healthy individuals MI patients' samples. Precise EV endocan levels can help us in predicting and following up on ischemia and hypoxia possibility in human cardiac tissue.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesProteoglycansExtracellular VesiclesMyocardial InfarctionNeoplasm ProteinsHumansGoldElectrochemical TechniquesTitaniumHuman Umbilical Vein Endothelial CellsOxidesCalcium CompoundsCobaltAngiogenesis

Stichwörter der Autor:innen

AngiogenesisEndocanExtracellular vesiclesMyocardial infarctionPerovskite-based electrochemical sensing

Substanzen

ESM1 protein, humanProteoglycansGoldNeoplasm ProteinsTitaniumOxidesCalcium CompoundsCobalt

Autor:innen und Institutionen

  • Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.
  • Stem Cell Research Center, Tabriz University of Medical Sciences, Tabriz, Iran. Electronic address: balalkhalilzadeh@gmail.com.
  • Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran; Chemistry and Chemical Engineering department, Khazar University, 41 Mehseti Street, Baku, AZ1096, Azerbaijan. Electronic add…
  • Stem Cell Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Department of Applied Cell Sciences, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran. Electronic…
  • Department of Physics, Faculty of Science, University of Sakarya, Sakarya, Turkey. Electronic address: ali.niaei@gmail.com.

Förderung

  • Tabriz University of Medical Sciences
  • Stem Cell Research Center, Tabriz University of Medical Sciences

Zitieren

APA

Dezhakam, E., Khalilzadeh, B., Naseri, A., Rahbarghazi, R., & Niaei, A. (2025). Au decorated-SrCu0.7Mn0.3O3 perovskite-based electrochemical biosensor for monitoring myocardial infarction angiogenesis response using extracellular vesicle endocan. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117768

Vancouver

Dezhakam E, Khalilzadeh B, Naseri A, Rahbarghazi R, Niaei A. Au decorated-SrCu0.7Mn0.3O3 perovskite-based electrochemical biosensor for monitoring myocardial infarction angiogenesis response using extracellular vesicle endocan. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117768

BibTeX
@article{Dezhakam2025,
  author = {Dezhakam, Ehsan and Khalilzadeh, Balal and Naseri, Abdolhossein and Rahbarghazi, Reza and Niaei, Aligholi},
  title = {Au decorated-SrCu0.7Mn0.3O3 perovskite-based electrochemical biosensor for monitoring myocardial infarction angiogenesis response using extracellular vesicle endocan},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117768}
}
Kostenlos starten →