Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Danial Khorsandi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Terasaki Institute for Biomedical Innovation, Los Angeles, CA, USA. Hauptthemen laut MEDLINE: Biosensing Techniques, Antibodies, Monoclonal, Immunoglobulin G. Die Arbeit nennt 95 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS, NIBIB NIH HHS, NCATS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The growing demand for monoclonal antibodies (mAbs) in biomedical applications requires efficient biomanufacturing processes with real-time monitoring capabilities to maximize production outputs cost-effectively. Currently, mAb production monitoring relies on end-point assays that fail to capture the real-time dynamics of mAb secretion. This study introduces a novel integrated system combining a photonic crystal structure in a total-internal-reflection (PC-TIR) biosensor with a microtranswell chip for the label-free and real-time monitoring of mAb secreted by hybridoma cell lines. This bioassay system accurately detects immunoglobulin G (IgG) in solution diffusing from the microtranswell, through the porous membrane, and to the evanescent field above the biosensor's top layer, generating standard curves with R2 > 0.99. Using W6/32 hybridoma cells, the biosensor monitors real-time mAb secretion rates with high sensitivity. Cell density and culture conditions, specifically fetal bovine serum (FBS) concentrations, correlate positively with mAb secretion rates. The biosensing platform can also differentiate mAb secretion rates among hybridoma clones raised against the same immunogen. The real-time monitoring capabilities of our novel platform offer a rapid, accurate, and scalable method for improving biomanufacturing processes and production of mAbs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesAntibodies, MonoclonalImmunoglobulin GAnimalsHybridomasEquipment DesignMiceHumans

Stichwörter der Autor:innen

Antibody secretion ratesBiomanufacturing monitoringHybridoma cellsMonoclonal antibodiesPhotonic crystalProtein concentrationReal-time detectionTotal-internal-reflection sensor

Substanzen

Antibodies, MonoclonalImmunoglobulin G

Autor:innen und Institutionen

  • Terasaki Institute for Biomedical Innovation, Los Angeles, CA, USA.
  • The University of Texas at San Antonio, Department of Biomedical Engineering and Chemical Engineering, One UTSA Circle, San Antonio, TX, 78249, USA.
  • University of Coimbra, Institute for Interdisciplinary Research, Doctoral Programme in Experimental Biology and Biomedicine (PDBEB), Portugal.
  • Terasaki Institute for Biomedical Innovation, Los Angeles, CA, USA. Electronic address: khademh@terasaki.org.
  • The University of Texas at San Antonio, Department of Biomedical Engineering and Chemical Engineering, One UTSA Circle, San Antonio, TX, 78249, USA. Electronic address: jingyong.ye@utsa.edu.
  • Terasaki Institute for Biomedical Innovation, Los Angeles, CA, USA. Electronic address: vjucaud@terasaki.org.

Förderung

  • NIAID NIH HHS
  • NIBIB NIH HHS
  • NCATS NIH HHS
  • NIGMS NIH HHS
  • National Science and Technology Council
  • National Institute of Biomedical Imaging and Bioengineering
  • National Institute of General Medical Sciences
  • Terasaki Institute for Biomedical Innovation

Zitieren

APA

Khorsandi, D., Yang, J. W., Trabucco, L., Ferrao, R., Ferreira, L., Dokmeci, M. R., Khademhosseini, A., Ye, J. Y., & Jucaud, V. (2025). Real-time and label-free monitoring of monoclonal antibody secretion rates using a PC-TIR biosensor. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117979

Vancouver

Khorsandi D, Yang JW, Trabucco L, Ferrao R, Ferreira L, Dokmeci MR, et al. Real-time and label-free monitoring of monoclonal antibody secretion rates using a PC-TIR biosensor. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117979

BibTeX
@article{Khorsandi2025,
  author = {Khorsandi, Danial and Yang, Jia-Wei and Trabucco, Luis and Ferrao, Rafaela and Ferreira, Lino and Dokmeci, Mehmet Remzi and Khademhosseini, Ali and Ye, Jing Yong and Jucaud, Vadim},
  title = {Real-time and label-free monitoring of monoclonal antibody secretion rates using a PC-TIR biosensor},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117979}
}
Kostenlos starten →