Everything’s under Control: Maximizing Biosensor Performance through Negative Control Probe Selection
Analytical Chemistry · 2025
DOI: 10.1021/acs.analchem.4c05854 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Joseph Bucukovski und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biochemistry and Biophysics, University of Rochester, Rochester, New York 14627, United States. Hauptthemen laut MEDLINE: Biosensing Techniques, Interleukin-17, C-Reactive Protein. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCATS NIH HHS, National Center for Advancing Translational Sciences.
Abstract (Originalsprache)
The rapid rise of label-free biosensing technologies has led to multiple creative strategies for the detection of macromolecules in complex biological solutions for disease state monitoring, drug discovery, and basic science research. A challenge with these techniques is that assays conducted in complex media such as serum suffer from nonspecific binding of matrix constituents. In label-free biosensors, it is virtually impossible to distinguish these nonspecific interactions without the use of a reference (negative control) probe. Only with reference subtraction can the specific binding signal be faithfully reported. To date, this has been a sparsely studied area in the biosensing field. Here, we report an FDA-inspired framework for optimum control probe selection and a systematic analysis for determining the optimal negative control probe given two monoclonal antibody capture probes on photonic ring resonator sensors. Briefly, while the differences in assay performance for IL-17A and CRP were found to be subtle, the best-scoring reference control based on the bioanalytical parameters of linearity, accuracy, and selectivity differed for each analyte. In the IL-17A assay, BSA scored the highest at 83%, while mouse IgG1 isotype control antibody placed a close second with 75%. With respect to the CRP assay, the rat IgG1 isotype control antibody scored the highest at 95%, while anti-FITC scored the second highest at 89%. These results suggest that although isotype-matching to the capture antibody may be tempting, the best on-chip reference control must be optimized on a case-by-case basis using the framework we report.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Biochemistry and Biophysics, University of Rochester, Rochester, New York 14627, United States.
- Institute of Optics, University of Rochester, Rochester, New York 14627, United States.
- Department of Dermatology, University of Rochester, Rochester, New York 14627, United States.
- Program in Materials Science, University of Rochester, Rochester, New York 14627, United States.
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14627, United States.
ORCID-Profile: Benjamin L Miller
Förderung
- NCATS NIH HHS
- National Center for Advancing Translational Sciences
Zitieren
APA
Bucukovski, J., & Miller, B. L. (2025). Everything’s under Control: Maximizing Biosensor Performance through Negative Control Probe Selection. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c05854
Vancouver
Bucukovski J, Miller BL. Everything’s under Control: Maximizing Biosensor Performance through Negative Control Probe Selection. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.4c05854
BibTeX
@article{Bucukovski2025,
author = {Bucukovski, Joseph and Miller, Benjamin L},
title = {Everything’s under Control: Maximizing Biosensor Performance through Negative Control Probe Selection},
journal = {Analytical Chemistry},
year = {2025},
doi = {10.1021/acs.analchem.4c05854}
}
EUVIMED