EUVIMEDEUVIMED entdecken
Crossref

Algorithm assisted comprehensive optimization of SPR sensors towards single molecule detection

Tingting Liu, Shiqi Hu, Shilei Ding, Lingling Zhang, Chu Yi, Yaofei Chen, Gui-Shi Liu, Zhe Chen, Wei Xiao, Lei Chen, Yunhan Luo, Donglin Cao

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117846 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Tingting Liu und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optoelectronic Engineering, College of Physics and Optoelectronic Engineering, Jinan University, Guangzhou, 510632, PR China; Guangdong…. Hauptthemen laut MEDLINE: Surface Plasmon Resonance, Biosensing Techniques, Algorithms, Single Molecule Imaging. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Planning Project of Shenzen Municipality, Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Detection of single molecules is a critical aspect of biochemistry, playing a vital role in understanding molecular interactions and functions. Surface plasmon resonance (SPR) biosensors are increasingly used for this purpose due to their ability to enable label-free and rapid monitoring. However, detecting low-concentration analytes down to the single-molecule level presents a substantial challenge for SPR sensors. This work introduces a multi-objective optimization strategy to enhance the performance of label-free SPR biosensors by improving various sensing metrics, including sensitivity, figure of merit, and depth of resonant dip. These enhancements lead to a significant improvement in the single-molecule detection capabilities of SPR sensors. Additionally, the k-means clustering method is applied to identify appropriate design parameters from the optimized parameter set, thereby mitigating the effects of processing errors on sensor performance. The developed SPR single molecule biosensor has demonstrated significant improvements in refractive index S, FOM, and DFOM, with increments of 230.22 %, 110.94 %, and 90.85 %, respectively. The optimized device was tested using mouse IgG to validate the improved sensing performance. Experimental findings indicate that this approach achieves a bulk refractive index sensitivity of 24,482.86 nm/RIU, a broad linear dynamic range from femtograms per milliliter (fg/mL) to micrograms per milliliter (μg/mL), and a detection limit as low as 54 ag/mL (0.36 aM). The multi-objective particle swarm optimization method proposed herein offers an efficient, rapid, and straightforward optimization strategy for SPR biosensors, facilitating ultra-sensitive single molecule detection with low limits of detection (LOD).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surface Plasmon ResonanceBiosensing TechniquesAlgorithmsSingle Molecule ImagingAnimalsMiceImmunoglobulin GEquipment DesignCluster Analysis

Stichwörter der Autor:innen

AlgorithmComprehensive optimizationLow LODSPR biosensors

Substanzen

Immunoglobulin G

Autor:innen und Institutionen

  • Department of Optoelectronic Engineering, College of Physics and Optoelectronic Engineering, Jinan University, Guangzhou, 510632, PR China; Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications…
  • The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou, 510632, PR China; Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Jinan University, Guangzhou,…
  • Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Jinan University, Guangzhou, 510632, PR China.
  • Department of Optoelectronic Engineering, College of Physics and Optoelectronic Engineering, Jinan University, Guangzhou, 510632, PR China; Guangdong Provincial Engineering Research Center for Electrical and Intelligent…
  • The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou, 510632, PR China.
  • Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Jinan University, Guangzhou, 510632, PR China. Electronic address: chenlei@jnu.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Planning Project of Shenzen Municipality
  • Fundamental Research Funds for the Central Universities
  • Basic and Applied Basic Research Foundation of Guangdong Province

Zitieren

APA

Liu, T., Hu, S., Ding, S., Zhang, L., Yi, C., Chen, Y., Liu, G. S., Chen, Z., Xiao, W., Chen, L., Luo, Y., & Cao, D. (2025). Algorithm assisted comprehensive optimization of SPR sensors towards single molecule detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117846

Vancouver

Liu T, Hu S, Ding S, Zhang L, Yi C, Chen Y, et al. Algorithm assisted comprehensive optimization of SPR sensors towards single molecule detection. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117846

BibTeX
@article{Liu2025,
  author = {Liu, Tingting and Hu, Shiqi and Ding, Shilei and Zhang, Lingling and Yi, Chu and Chen, Yaofei and Liu, Gui-Shi and Chen, Zhe and Xiao, Wei and Chen, Lei and Luo, Yunhan and Cao, Donglin},
  title = {Algorithm assisted comprehensive optimization of SPR sensors towards single molecule detection},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117846}
}
Kostenlos starten →