Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-12. Verfasst von N Fairuz Ain Zaini Ambia und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia. Electronic address: fairuzain04@gmail.com. Hauptthemen laut MEDLINE: Biosensing Techniques, Glucose, Polyamines, Blood Glucose. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Universiti Malaya, Malaysia Ministry of Higher Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study reports a highly sensitive, flexible, and intelligent microfluidic glucose biosensor integrating machine learning (ML)-optimized and laser-induced graphene (LIG) electrodes with electrodeposited polyamine saccharide-functionalized glucose oxidase (CS/GluOx) crosslinked with polyethene glycol (PEG). LIG fabrication parameters were optimized using a supervised ML model (random forest regression), achieving R2 = 0.92 and RMSE = 0.14 mC/cm2, while reducing fabrication time by 60 % and improving reproducibility. The CS/GluOx-PEG architecture enhanced catalytic efficiency and mechanical stability, maintaining >90 % of the signal after 250 CV cycles at 45° bending. Electrochemical measurements demonstrated linear glucose detection in the range 0.4-10 mM, with sensitivities of 18.0 μA (mM cm2)-1 (flat) and 17.6 μA (mM cm2)-1 (bent). Additionally, ML-based signal deconvolution enabled simultaneous real-time quantification of glucose and lactate in mixed samples, with RMSE values of 0.18 mM and 0.21 mM, respectively. Compared to current glucose sensors, this platform offers superior electrochemical performance, robustness and intelligent analyte discrimination, representing great potential for wearable CGM systems to improve diabetes management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesGlucosePolyaminesBlood GlucoseGlucose OxidaseGraphiteHumansElectrochemical TechniquesElectrodesMachine LearningEnzymes, ImmobilizedEquipment DesignPolyethylene Glycols

Stichwörter der Autor:innen

ChitosanFlexible biosensorGlucose oxidaseLIGMachine learningSmart microfluidic

Substanzen

Glucose OxidaseGraphiteGlucosePolyaminesEnzymes, ImmobilizedBlood GlucosePolyethylene Glycols

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia. Electronic address: fairuzain04@gmail.com.
  • Department of Chemistry, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia. Electronic address: shameerh@um.edu.my.
  • Department of Engineering and Sciences, American Degree Program, School of Liberal Arts and Sciences, Taylor's University, Taylor's Lakeside Campus, No. 1 Jalan Taylor, 47500, Subang Jaya, Selangor, Malaysia. Electronic…
  • Department of Physics, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia. Electronic address: shana@um.edu.my.
  • Department of Chemistry, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia. Electronic address: ndiana13@um.edu.my.

Förderung

  • Universiti Malaya
  • Malaysia Ministry of Higher Education

Zitieren

APA

Zaini Ambia, N. F. A., Hisham, S., Abu Bakar, N., Majid, S. R., & Nordin, N. (2025). Smart microfluidic biosensor with polyamine saccharide-GluOx-modified LIG electrodes and real-time ML signal deconvolution for glucose monitoring. Biosensors and Bioelectronics, 289, 117914. https://doi.org/10.1016/j.bios.2025.117914

Vancouver

Zaini Ambia NFA, Hisham S, Abu Bakar N, Majid SR, Nordin N. Smart microfluidic biosensor with polyamine saccharide-GluOx-modified LIG electrodes and real-time ML signal deconvolution for glucose monitoring. Biosensors and Bioelectronics. 2025;289:117914. doi:10.1016/j.bios.2025.117914

BibTeX
@article{ZainiAmbia2025,
  author = {Zaini Ambia, N Fairuz Ain and Hisham, Shameer and Abu Bakar, Nurfarhanim and Majid, S R and Nordin, Nurdiana},
  title = {Smart microfluidic biosensor with polyamine saccharide-GluOx-modified LIG electrodes and real-time ML signal deconvolution for glucose monitoring},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  volume = {289},
  pages = {117914},
  doi = {10.1016/j.bios.2025.117914}
}
Kostenlos starten →