EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Bioelectric Active Hydrogel Sensor for Trace Detection of Heavy Metal Ions in Livestock and Poultry Farm Wastewater

Heng-Chi Liu, Jia-Xin Du, Jie Wang, Junying Liu, Luyu Yang iD, Yang-Chun Yong iD

Biosensors · 2025

DOI: 10.3390/bios15060341 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Heng-Chi Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Energy Research, School of Environment and Safety Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China. Hauptthemen laut MEDLINE: Wastewater, Biosensing Techniques, Metals, Heavy, Water Pollutants, Chemical. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jiangsu Distinguished Professor Project, Jiangsu University Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heavy metal contamination in livestock and poultry farm wastewater poses significant risks to both the environment and human health, so it is critical to accurately and rapidly quantify heavy metal ion concentrations in water. This research develops a bioelectric active hydrogel sensor for detecting heavy metal ions in livestock wastewater. The sensor integrates microbial surface display technology with graphene hydrogel, displaying glucose oxidase (GOx) on the surface of yeast cells, and covalently incorporating it into the graphene hydrogel through the bio-reduction activity of metal-reducing bacteria, enhancing its electrochemical performance. The sensor demonstrates excellent sensitivity and stability in detecting Cu2+, with a detection limit for Cu2+ of 17.0 µM. This sensor is also applicable for detecting Zn2+ in wastewater. When various heavy metal ions coexist in the solution, they exert a more pronounced inhibitory effect on enzyme activity. Consequently, the sensor can be employed to assess the overall heavy metal content in water samples. In the detection of Cu2+ in real livestock and poultry wastewater, the recovery rate of the graphene hydrogel electrode ranged from 88% to 106.5%, indicating that the sensor holds significant potential for application in actual sample analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WastewaterBiosensing TechniquesMetals, HeavyWater Pollutants, ChemicalAnimalsLivestockPoultryHydrogelsGraphiteElectrodesFarmsGlucose OxidaseCopperElectrochemical Techniques

Stichwörter der Autor:innen

graphene hydrogelheavy metallivestock and poultry wastewatermicrobial surface displaysensors

Substanzen

WastewaterMetals, HeavyHydrogelsGraphiteWater Pollutants, ChemicalGlucose OxidaseCopper

Autor:innen und Institutionen

  • Institute for Energy Research, School of Environment and Safety Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013, China.

ORCID-Profile: Luyu Yang, Yang-Chun Yong

Förderung

  • Jiangsu Distinguished Professor Project
  • Jiangsu University Foundation

Zitieren

APA

Liu, H. C., Du, J. X., Wang, J., Liu, J., Yang, L., & Yong, Y. C. (2025). A Bioelectric Active Hydrogel Sensor for Trace Detection of Heavy Metal Ions in Livestock and Poultry Farm Wastewater. Biosensors. https://doi.org/10.3390/bios15060341

Vancouver

Liu HC, Du JX, Wang J, Liu J, Yang L, Yong YC. A Bioelectric Active Hydrogel Sensor for Trace Detection of Heavy Metal Ions in Livestock and Poultry Farm Wastewater. Biosensors. 2025. doi:10.3390/bios15060341

BibTeX
@article{Liu2025,
  author = {Liu, Heng-Chi and Du, Jia-Xin and Wang, Jie and Liu, Junying and Yang, Luyu and Yong, Yang-Chun},
  title = {A Bioelectric Active Hydrogel Sensor for Trace Detection of Heavy Metal Ions in Livestock and Poultry Farm Wastewater},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15060341}
}
Kostenlos starten →