EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Measurement of lactate concentration using a minimally invasive needle with non-planer optical waveguides

Daigo Koiwa, Yoichi Haga, Noriko Tsuruoka

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117557 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Daigo Koiwa und 2 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Engineering, Tohoku University, 6-6 Aza-Aoba, Aramaki, Aoba-ku, Sendai, Miagi, Japan. Hauptthemen laut MEDLINE: Biosensing Techniques, Lactic Acid. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Japan Science and Technology Agency, Japan Science and Technology Agency Fusion Oriented REsearch for disruptive Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Traditional methods for sampling biological substance concentrations in blood are invasive and unsuitable for continuous monitoring. This paper presents a minimally invasive device equipped with optical waveguides on the surface of an acupuncture needle for measuring lactate concentration in subepidermal tissue, potentially in a continuous fashion. The device utilizes absorbance measurements, based on the correlation between absorbance and lactate concentration in tissue. The needle, with a diameter of 200 μm, exhibits good penetrability, particularly when coated with a biocompatible epoxy, which reduces insertion resistance. The experimental results demonstrate that the device can successfully measure the concentration of lactate solutions, with light intensity decreasing as the lactate concentration increases. However, challenges remain in optimizing the device to reduce optical losses and enhance measurement accuracy. Future work will focus on reducing optical loss, conducting animal experiments, and developing a miniaturized system for simultaneous measurement of multiple biological substances, aiming for practical applications in daily health monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesLactic AcidNeedlesEquipment DesignAnimalsHumans

Stichwörter der Autor:innen

Lactate measurementMinimally invasiveNeedle typeNon-planar microfabricationOptical measurementsOptical waveguide

Substanzen

Lactic Acid

Autor:innen und Institutionen

  • Graduate School of Engineering, Tohoku University, 6-6 Aza-Aoba, Aramaki, Aoba-ku, Sendai, Miagi, Japan.
  • Graduate School of Engineering, Tohoku University, 6-6 Aza-Aoba, Aramaki, Aoba-ku, Sendai, Miagi, Japan. Electronic address: noriko.tsuruoka@tohoku.co.jp.

Förderung

  • Japan Society for the Promotion of Science
  • Japan Science and Technology Agency
  • Japan Science and Technology Agency Fusion Oriented REsearch for disruptive Science and Technology

Zitieren

APA

Koiwa, D., Haga, Y., & Tsuruoka, N. (2025). Measurement of lactate concentration using a minimally invasive needle with non-planer optical waveguides. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117557

Vancouver

Koiwa D, Haga Y, Tsuruoka N. Measurement of lactate concentration using a minimally invasive needle with non-planer optical waveguides. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117557

BibTeX
@article{Koiwa2025,
  author = {Koiwa, Daigo and Haga, Yoichi and Tsuruoka, Noriko},
  title = {Measurement of lactate concentration using a minimally invasive needle with non-planer optical waveguides},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117557}
}
Kostenlos starten →