Multi-functional, conformal systems with ultrathin crystalline-silicon-based bioelectronics for characterization of intraocular pressure and ocular surface temperature
Biosensors and Bioelectronics · 2025
DOI: 10.1016/j.bios.2024.116786 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Yuting Shao und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Tongji Eye Institute, Tongji Hospital, School of Medicine, Tongji University, Shanghai, 200065, People's Republic of Chi…. Hauptthemen laut MEDLINE: Intraocular Pressure, Biosensing Techniques, Glaucoma. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Science and Technology Commission of Shanghai Municipality, Guizhou Province Science and Technology Foundation, National Natural Science Foundation of China.
Abstract (Originalsprache)
Technologies that established in vivo evaluations of soft-tissue biomechanics and temperature are essential to biological research and clinical diagnostics, particularly for a wide range of eye-related diseases such as glaucoma. Of importance are advanced bioelectronic devices for high-precise monitoring of intraocular pressure (IOP) and various ocular temperatures, as clinically proven uses for glaucoma diagnosis. Existing characterization methods are temporary, single point, and lack microscale resolution, failing to measure continuous IOP fluctuation across the long-term period. Here, this work presents a multi-functional smart contact lens, capable of rapidly capturing IOP fluctuation and ocular surface temperature (OST) for assistance for clinical use. The microscale device design is programmable and determined by finite element analysis simulation, with detailed experiments of ex vivo porcine eyeballs. Such compact bioelectronics can provide high-precise measurement with sensitivity of 0.03% mmHg-1 and 1.2 Ω °C-1 in the range of Δ2∼50 mmHg and 30-50 °C, respectively. In vivo tests of bio-integration with a living rabbit can evaluate real-time IOP fluctuation and OST, as of biocompatibility assessments verified through cellular and animal experiments. The resultant bioelectronic devices for continuous precise characterization of living eyeballs can offer broad utility for hospital diagnosis of a wide range of eye-related disorders.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology, Tongji Eye Institute, Tongji Hospital, School of Medicine, Tongji University, Shanghai, 200065, People's Republic of China; Shanghai Frontiers Science Research Base of Intelligent Optoelectr…
- Department of Materials Science & State Key Laboratory of Molecular Engineering of Polymers, Fudan University, Shanghai, 200438, People's Republic of China.
- Department of Ophthalmology, Guizhou Provincial People's Hospital, Guiyang, 550000, People's Republic of China.
- School of Mechanics and Aerospace Engineering, State Key Laboratory of Structural Analysis, Optimization and CAE Software for Industrial Equipment, and International Research Center for Computational Mechanics, Dalian U…
- Department of Ophthalmology, Tongji Eye Institute, Tongji Hospital, School of Medicine, Tongji University, Shanghai, 200065, People's Republic of China.
- Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Institute of Optoelectronics, Fudan University, Shanghai, 200438, People's Republic of China.
Förderung
- Science and Technology Commission of Shanghai Municipality
- Guizhou Province Science and Technology Foundation
- National Natural Science Foundation of China
Zitieren
APA
Shao, Y., Hu, B., Liu, X., Ni, Z., Shu, Y., Zhang, X., Shen, J., Liang, L., Zhou, L., Liu, J., Li, X., Zhang, J., Ma, L., Di, Z., Mei, Y., Li, R., Bi, Y., & Song, E. (2025). Multi-functional, conformal systems with ultrathin crystalline-silicon-based bioelectronics for characterization of intraocular pressure and ocular surface temperature. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116786
Vancouver
Shao Y, Hu B, Liu X, Ni Z, Shu Y, Zhang X, et al. Multi-functional, conformal systems with ultrathin crystalline-silicon-based bioelectronics for characterization of intraocular pressure and ocular surface temperature. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2024.116786
BibTeX
@article{Shao2025,
author = {Shao, Yuting and Hu, Bofan and Liu, Xin and Ni, Zhuofan and Shu, Yiyang and Zhang, Xiruo and Shen, Jiaqi and Liang, Li and Zhou, Lianjie and Liu, Junhan and Li, Xiao and Zhang, Juan and Ma, Lichao and Di, Zengfeng and Mei, Yongfeng and Li, Rui and Bi, Yanlong and Song, Enming},
title = {Multi-functional, conformal systems with ultrathin crystalline-silicon-based bioelectronics for characterization of intraocular pressure and ocular surface temperature},
journal = {Biosensors and Bioelectronics},
year = {2025},
doi = {10.1016/j.bios.2024.116786}
}