Biomechanical Relationships Between the Aqueous Veins and Perilimbal Sclera During Intraocular Pressure Regulation
Translational Vision Science & Technology · 2025
DOI: 10.1167/tvst.14.10.9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2025. Verfasst von Linyu Ni und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Visual Sciences, Kellogg Eye Center, University of Michigan, Ann Arbor, MI, USA. Hauptthemen laut MEDLINE: Intraocular Pressure, Sclera, Aqueous Humor, Glaucoma. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
A major assumption of microinvasive glaucoma surgeries (MIGS) is that effective intraocular pressure (IOP) reduction can be achieved by enhancing aqueous humor (AH) outflow into the aqueous veins. However, this IOP outcome is not predictable in part due to lack of knowledge concerning the role of tissue biomechanics on AH outflow through the distal aqueous veins within the perilimbal sclera (PLS). The purpose of this study is to investigate the biomechanical response of the aqueous veins and the PLS and their interaction during IOP.
Methods
Optical resolution photoacoustic microscopy were implemented to capture the 3D deformations of the aqueous veins and in the surrounding PLS during aqueous outflow in porcine and human whole globes. Partial trabeculotomy was performed to minimize the contribution of the trabecular meshwork to the outflow resistance.
Results
The deformations of the tissue components and the IOP were measured in both porcine and human eyes. Strong correlations were found among the relative cross-sectional area of the aqueous veins, strains in the PLS in porcine eyes, and the steady-state (SS) IOP of porcine eyes.
Conclusions
The data shows that stiff PLS restricts vein cross-sectional area and results in overall higher SS IOP in an eye. Translational Relevance: The findings in this study suggest the potential for predicting the limit of effectiveness of an MIGS given knowledge of the interactive behaviors of the aqueous veins and PLS in an eye.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology and Visual Sciences, Kellogg Eye Center, University of Michigan, Ann Arbor, MI, USA.
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
- Department of Mechanical Engineering, University of Michigan-Dearborn, Dearborn, MI, USA.
- Department of Ophthalmology and Visual Sciences, Havener Eye Institute, The Ohio State University Wexner Medical Center, Columbus, OH, USA.
Förderung
- NEI NIH HHS
Zitieren
APA
Ni, L., Warchock, A., Krawczyk, E., Kim, W., Moroi, S. E., Xu, G., & Argento, A. (2025). Biomechanical Relationships Between the Aqueous Veins and Perilimbal Sclera During Intraocular Pressure Regulation. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.14.10.9
Vancouver
Ni L, Warchock A, Krawczyk E, Kim W, Moroi SE, Xu G, et al. Biomechanical Relationships Between the Aqueous Veins and Perilimbal Sclera During Intraocular Pressure Regulation. Translational Vision Science & Technology. 2025. doi:10.1167/tvst.14.10.9
BibTeX
@article{Ni2025,
author = {Ni, Linyu and Warchock, Alexus and Krawczyk, Erik and Kim, Wonsuk and Moroi, Sayoko E and Xu, Guan and Argento, Alan},
title = {Biomechanical Relationships Between the Aqueous Veins and Perilimbal Sclera During Intraocular Pressure Regulation},
journal = {Translational Vision Science & Technology},
year = {2025},
doi = {10.1167/tvst.14.10.9}
}
EUVIMED