Exploring the Feasibility of Estimating Intraocular Pressure Using Vibrational Response of the Eye: A Methodological Approach
Sensors · 2024
DOI: 10.3390/s24123997 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Seongwook Jeon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea. Hauptthemen laut MEDLINE: Intraocular Pressure, Vibration, Tonometry, Ocular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation (NRF) funded by the Korean government (MSIT), Bio & Medical Technology Development Program of the National Research Foundation (NRF) funded by the Korean government (MSIT).
Abstract (Originalsprache)
This study addresses the limitations of current tonometry techniques by exploring vibroacoustic properties for estimating intraocular pressure (IOP), a key diagnostic parameter for monitoring glaucoma—a significant risk factor for vision loss. Utilizing vivo porcine eyeballs, we investigated the relationship between IOP and the nonlinear vibration transfer function ratio (NVTFR). Through applying varying vibration levels and analyzing responses with transfer function analysis and univariate regression, we identified a strong negative correlation between NVTFR and IOP, evidenced by a Pearson correlation coefficient of −0.8111 and significant results from generalized linear model (GLM) regression (p-value < 0.001). These findings indicate the potential of NVTFR as a vital indicator of IOP changes. Our study highlights the feasibility of using vibroacoustic properties, specifically NVTFR, to measure IOP. While further refinement is necessary for in vivo application, this approach opens new possibilities for non-invasive and patient-friendly IOP monitoring, potentially enhancing ophthalmology diagnostic techniques and providing a foundation for future research and development in this critical area.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea.
- Department of Ophthalmology, Hanyang University College of Medicine, Seoul 04763, Republic of Korea.
- Department of Ophthalmology, Hanyang University Seoul Hospital, Seoul 04763, Republic of Korea.
ORCID-Profile: Gyungmin Toh, Junhong Park, Won June Lee
Förderung
- National Research Foundation (NRF) funded by the Korean government (MSIT)
- Bio & Medical Technology Development Program of the National Research Foundation (NRF) funded by the Korean government (MSIT)
Zitieren
APA
Jeon, S., Toh, G., Park, J., & Lee, W. J. (2024). Exploring the Feasibility of Estimating Intraocular Pressure Using Vibrational Response of the Eye: A Methodological Approach. Sensors. https://doi.org/10.3390/s24123997
Vancouver
Jeon S, Toh G, Park J, Lee WJ. Exploring the Feasibility of Estimating Intraocular Pressure Using Vibrational Response of the Eye: A Methodological Approach. Sensors. 2024. doi:10.3390/s24123997
BibTeX
@article{Jeon2024,
author = {Jeon, Seongwook and Toh, Gyungmin and Park, Junhong and Lee, Won June},
title = {Exploring the Feasibility of Estimating Intraocular Pressure Using Vibrational Response of the Eye: A Methodological Approach},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24123997}
}
EUVIMED